44
User’s Manual
PMX_MULTI
Basic Functions | CONFIG Settings
Displaying and setting CONFIG parameters
CF00 and CF40 are execution parameters of functions. For the execution procedure, see the details of
each CONFIG parameter.
1
Use the CONFIG key and the VOLTAGE knob to select the CONFIG parameter you
want to set.
The voltmeter displays the parameter number. The ammeter displays the corresponding setting.
Parameters that can be set separately for each channel are displayed on all channels.
Parameters that are set to the same value on all channels are displayed only in the CH2 display
area.
Each time you press CONFIG, the parameter number changes in the following order:
CF00
→
CF20
→
CF30
→
CF40
→
CF50
→
CF60
→
measurement display. Turning the VOLTAGE knob
changes the ones digit.
Pressing LOCAL changes the parameter number to the mnemonic display. Turning the VOLTAGE
knob while holding down the LOCAL key switches the CONFIG parameter while retaining the mne-
monic display.
2
Turn the CURRENT knob to change the value of the parameter.
3
To specify or display other parameters, repeat step 1 and step 2.
4
Hold down CONFIG until the measurement display appears or press SET to exit
from CONFIG settings.
There are parameters whose values are applied immediately, those whose values are applied after
the power is turned off and then back on, and those whose values are applied when [
APPL
] is
executed using CF40
.
This completes the setting.
C
B
A
CLR
OVP
࣭
OCP
ET
LOCK
CONFIG
SELECT
OUTPUT
CH3
SELECT
OUTPUT
CH4
FINE
CURRENT
FINE
VOLTAGE
LOCAL
SHIF T
CV
V
s
OFF
CC
A
s
ON
PRL
SER
TRACKING 12
CV
V
s
OFF
CC
A
s
ON
PRL
SER
TRACKING 12
%
%
%
%
Setting display
VOLTAGE knob
Select the parameter number.
CURRENT knob
Select the value or the
parameter to display.
CONFIG key Select the parameter number.
Parameter number CF (CONFIG) + a two-digit number
or a mnemonic display
CONFIG setting and display examples
(Example of PMX32-2QU)