40
DME1600
Status Reporting Commands
SYST:ERR
Queries the DME1600 error queue. Up to 20 errors can be stored in the queue. Errors are
retrieved in first in, first out (FIFO) order. Each error line can be up to 80 characters long.
Command
SYSTem:ERRor?
STAT:QUES:ENAB
Enables bits in the questionable data enable register. The selected bits are reported to the
status byte.
Command
STATus:QUEStionable:ENABle <enable value>
STATus:QUEStionable:ENABle?
Response
In response to STAT:QUES:ENAB?, the DME1600 returns a binary-weighted decimal
representing the bits set in the enable register.
STAT:QUES:EVEN
Queries the questionable data event register.
Command
STATus:QUEStionable:EVENt?
Response
In response to STAT:QUES:EVEN?, the DME1600 returns a decimal value that corresponds
to the binary-weighted sum of all bits set in the register.
STAT:PRES
Clears all the bits in the questionable data enable register.
Command
STATus:PRESet
*CLS
Clears the status byte summary register and all event registers.
Command
*CLS
*ESE
Enables bits in the standard event enable register. The selected bits are reported to the sta-
tus byte.
Command
*ESE <enable value>
*ESE?
Response
In response to *ESE?, the DME1600 returns a decimal value that corresponds to the binary-
weighted sum of all bits set in the register.
Содержание DME1600
Страница 4: ...4 DME1600 This page left blank intentionally...
Страница 5: ...Setup This chapter explains the settings that you need to configure to use the interfaces 1...
Страница 9: ...Message Reference This chapter explains the SCPI com mands 2 Message Reference...
Страница 43: ...Appendix A Error Messages B Sample Programs...
Страница 55: ......