Math Function Commands
CALC:AVER:AVER
Returns the average of all the measured values that have been acquired since the maximum
and minimum math function was enabled. This value is cleared when you turn the maximum
and minimum math function off, turn off the power, or reset the remote interface settings.
Command
CALCulate:AVERage:AVERage?
CALC:AVER:COUN
Returns the number of measured values that have been acquired since the maximum and
minimum math function was enabled. This value is cleared when you turn the maximum and
minimum math function off, turn off the power, or reset the remote interface settings.
Command
CALCulate:AVERage:COUNt?
CALC:NULL:OFFS
Saves a null value to the DME1600’s null register. Before you save a value to the math regis-
ter, you must turn the math function on. The null value can be set to a value from 0 to ±120 %
of the maximum range.
Command
CALCulate:NULL:OFFSet {<value>|MINimum|MAXimum}
CALCulate:NULL:OFFSet?
Response
In response to CALC:NULL:OFFS?, the DME1600 returns the null value.
CALC:LIM:LOW
Sets the lower limit for upper and lower limit testing. In relation to the percentage function, the
lower limit can be set to a value from 0 to ±120 % of the maximum range.
Command
CALCulate:LIMit:LOWer {<value>|MINimum|MAXimum}
CALCulate:LIMit:LOWer?
Response
In response to CALC:LIM:LOW?, the DME1600 returns the lower limit for upper and lower
limit testing.
CALC:LIM:UPP
Sets the upper limit for upper and lower limit testing. In relation to the percentage function,
the upper limit can be set to a value from 0 to ±120 % of the maximum range.
Command
CALCulate:LIMit:UPPer {<value>|MINimum|MAXimum}
CALCulate:LIMit:UPPer?
Response
In response to CALC:LIM:UPP?, the DME1600 returns the upper limit for upper and lower
limit testing.
CALC:MXB:MMF
Sets the value of M for the MX+B math function.
Command
CALCulate:MXB:MMFactor {<value>|MINimum|MAXimum}
CALCulate:MXB:MMFactor? [MINimum|MAXimum]
Содержание DME1600
Страница 4: ...4 DME1600 This page left blank intentionally...
Страница 5: ...Setup This chapter explains the settings that you need to configure to use the interfaces 1...
Страница 9: ...Message Reference This chapter explains the SCPI com mands 2 Message Reference...
Страница 43: ...Appendix A Error Messages B Sample Programs...
Страница 55: ......