Command Errors (continued)
108
Parameter not allowed
More parameters were received than were expected.
109
Missing parameter
Fewer parameters were received than were expected.
110
Command header error
An error was detected in the header.
111
Header separator error
A character that was not a valid header separator was found in the command string.
112
Program mnemonic too long
The header contains more than 12 characters.
113
Undefined header
A command was received that was not valid for this instrument.
114
Header suffix out of range
The value of the numeric suffix is not valid.
120
Numeric data error
Generic numeric data error.
121
Invalid character in number
An invalid character for the data type was found in the command string.
123
Exponent too large
The magnitude of the exponent was larger than 32000.
124
Too many digits
The mantissa of a numeric parameter contained more than 255 digits, excluding leading zeros.
128
Numeric data not allowed
A numeric parameter was received but a character string was expected.
130
Suffix error
Generic suffix error
131
Invalid suffix
A suffix was incorrectly specified for a numeric parameter.
134
Suffix too long
The suffix contains more than 12 characters.
138
Suffix not allowed
A suffix is not supported for this command.
140
Character data error
Generic character data error
141
Invalid character data
Either the character data element contains an invalid character, or the element is not valid.
144
Character data too long
The character data element contains more than 12 characters.
148
Character data not allowed
A discrete parameter was received, but a string or numeric parameter was expected.
150
String data error
Generic string data error
151
Invalid string data
An invalid character string was received. Check that the string is enclosed in quotation marks.
158
String data not allowed
A character string was received, but is not allowed for this command.
160
Block data error
Generic block data error
161
Invalid block data
The number of data bytes sent does not match the number of bytes specified in the header.
Содержание N6705
Страница 1: ...Service Guide Keysight N6705 DC Power Analyzer ...
Страница 8: ......
Страница 104: ......
Страница 116: ......
Страница 120: ...6 Replaceable Parts 120 Model N6705 Service Guide Parts Location Diagrams Figure 6 1 External Parts ...
Страница 121: ...Replaceable Parts 6 Model N6705 Service Guide 121 Figure 6 2 Top Cover Removed ...
Страница 122: ...6 Replaceable Parts 122 Model N6705 Service Guide Figure 6 3 Top Chassis Removed ...
Страница 123: ...Replaceable Parts 6 Model N6705 Service Guide 123 Figure 6 4 Front Panel Figure 6 5 Handle Assembly ...
Страница 124: ......
Страница 132: ......