Keysight M9521A Скачать руководство пользователя страница 30

30

Keysight M9521A AXIe System Module Startup Guide

Host PC/Chassis Interface Topics

7

PCIe is logically an extension of the host PC backplane. If the PCIe interface is 

used to connect to the chassis, the chassis NIC appears to Windows as if it is 

installed directly in the PC. 
If you are using the PCIe interface to connect to the Keysight AXIe chassis, an 

Intel PCIe-to-LAN network adapter in the chassis will appear to Windows as a 

locally installed device in your PC. Most Windows versions provide the 

necessary Intel network driver for this adapter.
However, if you see the 'Found New Hardware Wizard' dialog on your PC, and 

if the dialog indicates that software needs to be installed for an Ethernet 

Controller, you will need to install the Intel PROWin32.exe network driver on 

your PC. To install this driver, please see the Intel instructions for the 

PROWin32.exe driver.
If you are interfacing to the chassis using only its LAN interface, the 

PCIe-to-LAN network adapter will not be visible to your PC, and the 

aforementioned driver does not need to be installed.

8

If the chassis is connected only to LAN, the chassis will attempt to obtain an 

IP address using DHCP.

9

If both PCIe and LAN are connected to the chassis, the LAN VISA resource 

name is used to connect to the chassis.

10

Do not attach a LAN cable after communications has been established over 

the PCIe cable. Doing this will disrupt PCIe communications, and will not 

provide LAN communications — the chassis will become inaccessible and 

rebooting of the PC will be required to restore communications.
If you need both LAN and PCIe communications, connect 

both

 cables prior to 

powering-up the chassis.

11

If you have connected to the chassis using PCIe and/or LAN, and want to 

visually confirm that you are, in fact, communicating to the chassis that you 

believe you are communicating to, you can click the

 Turn on Front Panel 

Identification Indicator 

link on the Web Interface home page as highlighted 

below. This will flash the STATUS LED of the chassis you are interfacing to.

Содержание M9521A

Страница 1: ...Keysight M9521A AXIe System Module ASM Startup Guide...

Страница 2: ......

Страница 3: ...rights in excess of these rights customarily provided to the public to use modify reproduce release per form display or disclose commercial computer software or commercial com puter software document...

Страница 4: ...erform proce dures involving cover or shield removal unless you are qualified to do so DO NOT operate damaged equipment Whenever it is possible that the safety protection features built into this prod...

Страница 5: ...at this ISM device complies with the Canadian ICES 001 This symbol represents the time period during which no hazardous or toxic substance elements are expected to leak or deteriorate during normal us...

Страница 6: ...vi...

Страница 7: ...First then the Host Controller 19 Step 6 Install IO Libraries Suite and Connect to the Web Interface 21 Host PC Requirements 21 Installing the Keysight IO Libraries Suite 22 Using Keysight Connection...

Страница 8: ...viii Keysight M9521A AXIe System Module Startup Guide...

Страница 9: ...the ASM and other installed modules appropriate control software and instrument drivers must be installed on the host PC This Startup Guide plus additional information can be found in PDF format on th...

Страница 10: ...pression 4 IN Accepts an externally sourced timing input Input range 5V peak AC coupled 50 terminated 250 mV minimum swing 5 OUT Extends the internal clock source to external instruments 3 3V AC coupl...

Страница 11: ...icant level of ESD protection Of the two only the table mat and wrist strap combination provides adequate ESD protection when used alone To ensure user safety the static safe accessories must provide...

Страница 12: ...hat you ordered This printed document Keysight M9521A AXIe System Module Startup Guide An AXIe Chassis and Controller Software and Product Information CD M9514 10001 This CD contains software drivers...

Страница 13: ...hen fully open the handles by pivoting them out towards you until they are perpendicular to the front panel The left handle is shown below from the top view correctly extended 5 Slide the ASM complete...

Страница 14: ...ectricity To minimize electrostatic damage take the necessary anti static precautions Some AXIe chassis provide a grounding terminal on the front panel to which you can connect a wrist strap Empty Slo...

Страница 15: ...re details The following table indicates the various states colors of the ASM Status LED and its general meaning LED State color Description M9521A ASM Status LED off ASM not receiving power Chassis p...

Страница 16: ...ed state or circuit is working normally Refer to the M9514A Startup Guide or M9514A and M9521A User Guide for information on the chassis STATUS LEDs Verify the STATUS LEDs on your ASM and the AXIe cha...

Страница 17: ...nframe a current list can be found at www keysight com find axie chassis If you decide to use an embedded controller module as your host PC you need to install the controller in the chassis before pro...

Страница 18: ...c connection For additional host PC and chassis ASM interface information refer to Host PC Chassis Interface Topics on page 28 of this guide Also refer to the M9514A and M9521A User Guide Except where...

Страница 19: ...ashing green you can turn on your PCIe connected controller You can also view the chassis web interface or bring up the chassis SFP ASM power high ASM powered up by Shelf Manager Chassis ASM and Exter...

Страница 20: ...e chassis must be powered down before modules are added or removed While the power sequencing shown above does not apply to an embedded controller because an embedded controller and chassis are powere...

Страница 21: ...equired software Microsoft NET Keysight IO Libraries version 17 1 or later and chassis device drivers the host PC requires the following Keysight s M9536A AXIe Embedded Controller requires Windows Emb...

Страница 22: ...properly enumerate PCIe devices in the AXIe chassis at www keysight com find axie chassis Keysight s M9536A Embedded Controller must have BIOS AG16 or later If you are using a Keysight embedded contr...

Страница 23: ...on on your desktop double click the icon to launch the program b From a Command Prompt window type c Program Files Keysight IO Libraries Suite KeysightConnectionExpert exe to launch the program This s...

Страница 24: ...cted Note also that the ASM soft front panel SFP provides significant additional functionality to the Web Interface However using the Web Interface requires only a browser on the host PC whereas using...

Страница 25: ...is a brief description of what you can do on each page ASM Firmware Version Home Page View General Information about the ASM such as product identification firmware version and LAN parameters LAN Conf...

Страница 26: ...configure On the M9514A LAN Configuration Web Page and the M9521A LAN Configuration Web Page there is a button labeled Reset User Settable Memory This button resets all user settable non volatile mem...

Страница 27: ...Information CD in the host PC If you do not have the CD or a CD drive on your PC you can download the most recent version of the SFP and drivers at www keysight com find M9521A 2 Select the M9521A me...

Страница 28: ...may be of assistance in establishing a connection between the host PC and the ASM Unless otherwise noted these topics relate to interfacing to the ASM itself not to other modules in the chassis slots...

Страница 29: ...ill be displayed by Keysight Connection Expert under the PXIO label not under the LAN label 5 For a PCIe connection to the chassis a private IP address beginning with 169 254 will be assigned If a dir...

Страница 30: ...only its LAN interface the PCIe to LAN network adapter will not be visible to your PC and the aforementioned driver does not need to be installed 8 If the chassis is connected only to LAN the chassis...

Страница 31: ...Keysight M9521A AXIe System Module Startup Guide 31 Host PC Chassis Interface Topics...

Страница 32: ...return address Product model number for example M9521A Product serial number for example TWXXXXXXXX The serial number label is located on the side of the module A description of failure or service req...

Страница 33: ...ng user replaceable assemblies and accessories are available from Keysight Only Keysight approved accessories shall be used Other parts originally supplied with the AXIe System Module or chassis may b...

Страница 34: ...sis do not have a system slot Environmental Operating and storage conditions Operating Storage Temperature 0 C to 50 C 25 C to 60 C Altitude up to 3000 meters up to 4600 meters Humidity Type tested at...

Страница 35: ...010 1 Canada CSA C22 2 No 61010 1 USA UL std no 61010 1 EMC Complies with European EMC Directive IEC EN 61326 1 CISPR Pub 11 Group 1 Class A AS NZS CISPR 11 ICES NMB 001 This ISM device complies with...

Страница 36: ...36 Keysight M9521A AXIe System Module Startup Guide Safety Related Specifications...

Страница 37: ...37...

Страница 38: ...This information is subject to change without notice Keysight Technologies 2017 Edition 10 December 2017 Published in USA M9521 90001 www keysight com...

Отзывы: