3
Programming
238
Keysight 53147A/148A/149A Operating and Programming Guide
The supported
<sensor_function>
strings are:
“[XNONe:]FREQuency [1 | 2]”
“[XNONe:]POWer [3]”
“[XNONe:]VOLTage[:DC] [4]”
QUERY
RESPONSE
– The query form of this command returns a comma-separated list of functions
that are
ON
.
– The string omits default nodes (
XNONe
) and uses short-form mnemonics. If
the channel specifier(s) are set to default value(s), no channel specifier is
returned in response. If the channel specifier(s) are not set to default value(s),
they are returned in the response with a single space separating the first
channel specifier from the function name.
For example:
–
“FREQ”
is returned for frequency on Channel 1.
–
“FREQ 2”
is returned for frequency on Channel 2.
– The only functions that can be turned ON simultaneously are
“POW 2”
and
“FREQ 2”.
COMMENTS
– *RST: “FREQ 1”
– This command can be used to turn individual function(s) ON without affecting
other functions.
– If the optional channel specification is omitted from the
<sensor_function>
, a
default channel selection is made. For Frequency and Power, the default is
Channel 2.
RELATED
FRONT-PANEL
KEYS
Various
COMMAND
[:SENSe]:FUNCtion:STATe? . . . <sensor_function>
This query-only command returns a Boolean value that indicates whether the
specified
<sensor_function>
is currently
ON
or
OFF
.
COMMENT
See
[:SENSe]:FUNCtion[:ON]
on page 237 for valid
<sensor_function>
strings.