29
EN
PARAMETERS
DESCRIPTION
DEFAULT MIN MAX UNIT
TYPE
5
iE
.
D
.
Sensitive edge tripping mode
0= only tripped during closure with direction reversal
1 = stops the automation (during both opening and
closure) and retreats from the obstacle
0
0
1
SL/BA/
OH
6
tE
.
D
.
Edge test
0 = off
1 = on
0
0
1
SL/BA/
OH
7
LP
.
o
.
Parcial opening
50
10
100
%
SL
8
TP
.
C
.
Time for automatic closure from parcial opening
(0=off)
0
0
900
s
SL
9
FP
.
r
.
Flashing light output setup
0 = Steady
1 = Flashing
2 = Two-colour LED strip for barrier (MODE 1)
- gate closed steady red
- gate open LEDs off
- during opening flashing green
- during closing flashing red
- stopped not on limit switch flashing red
3 = two-colour LED strip for barrier (MODE 2)
- gate closed steady red
- gate open steady green
- during opening flashing green
- during closing flashing red
- stopped not on limit switch flashing red
N.B.: if this parameter is set as 2 or 3, the settings
of parameter
IN.D.
will be ignored.
If this parameter is set as 2 or 3, the flashing
light and gate open light outputs will be used for
operation with the LED strip
1 *
0
3
SL/BA/
OH
10
tP
.
r
.
Pre-flashing time (0 = off)
0
0
20
s
SL/BA/
OH
11
FC
.
Y
.
Courtesy light setup
0 = On at end of operation for time TCY
1 = On if gate not duration of TCY
2 = On if courtesy light timer (TCY) time not out
0
0
2
SL/BA/
OH
12
tC
.
Y
.
Courtesy light on time
0
0
900
s
SL/BA/
OH
13
CL
.
E
.
Clearance. Allows to stop before the fully open
position: it is useful to avoid mechanical stress
during opening.
0
0
30
%
BA/OH
14
de
.
a
.
Hold-to-run
0 = off
1 = on
0
0
1
SL/BA/
OH
15
IN
.
D
.
0 = deactivated
1 = gate open light ON/OFF
2 = gate open light proportional
- Slow flashing with gate opening
- Quick flashing with gate closing
- Steady light if gate open
- 2 f pause with gate stationary (position
other than closed)
3 = Electric lock
4 = Magnetic electric lock function with output active
when gate/door is closed
N.B. interface with an external relay with 24 Vdc
winding. To activate this function, the pre-flash must
be enabled at the recommended value of 1 sec (tP.r.
≠ 0)
5 = LED strip for gate open light (MODE 1)
- steady light when open and closed
- flashing light in all other positions
6 = LED strip for gate open light (MODE 2)
- gate closed steady red
- gate open LEDs off
flashing red in all other positions
0
0
6
SL/BA/
OH
16
se
.
r
.
Service interval cycle threshold.
(0 = off)
10
0
200
x 1000
cicli
SL/BA/
OH