![Key Automation CT102 24 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/key-automation/ct102-24/ct102-24_instructions-and-warnings-for-installation-and-use_1960071030.webp)
30
EN
PARAMETRI
DESCRIZIONE
DEFAULT MIN MAX UNITÀ
17
se
.
f
.
Enabling of continuous flashing indicating
service required with se.r. ≠ 0 (only active with gate
closed).
0 = off
1 = on
0
0
1
SL/BA/
OH
18
EL
.
T
.
Electric lock activation time in seconds
4
1
10
s
SL/BA/
OH
19
ST
.
P
.
High-speed motor start-up.
0 = on
1 = off
0
0
1
SL/BA/
OH
20
EN
.
C
.
1 = Off (use of virtual encoder)
2 = On (use of motor’s physical encoder)
1
1
2
SL/BA/
OH
21
NE
.
P
.
1 to 10 pulses per revolution of the physical encoder
4
1
10
SL/BA/
OH
22
DE
.
F
.
0 = Restore of factory settings for sliding gate motor
SC4224
1 = Restore of factory settings for sliding gate motor
SUN4224
2 = Restore of factory settings for sliding gate motor
SUN7224, SC7224
3 = Restore of factory settings for sliding gate motor
SUN11224, SC11224
4 = Factory setting restore for 4/6 mt barrier and up-
and-over door
5 = Factory setting restore for 8 mt barrier
0
0
5
SL/BA/
OH
To set the default values: 1) access the advanced programming
function; 2) select the “dEf” parameter”; 3) activate the modification
mode (“0” on display”); 4) accept the modification (press “MENU”
and hold it down). A countdown should now appear: 49,48...,1
down to “don“. Release the button when finished.
To use both colours of a two-colour LED strip, make the connections
as explained in the CTLIGHT instructions and modify parameters
FP
.
r
. as required (setting 2 or 3).
To use just one colour of a LED strip, make the connections as
explained in the CTLIGHT instructions and modify parameter
IN
.
D
.
as required (setting 5 or 6); parameter
FP
.
r
. cannot be set on 2
or 3.
* = The default value for barriers is 3