23
EN
ELECTRICAL CONNECTIONS FOR ENERGY SAVING
NEG
PH-POW
STOP
STOP
PH 2
COM
FLASH
IND
LED
24 VAC
24 VAC
PH 1
OPEN
CLOSE
SBS
PAR
COM
PHOTOTEST
OUTPUT LED
OPEN
PHOTOCELL 1
PHOTOCELL 2
CLOSE
PARCIAL
STEP BY STEP
COMMON
STOP/EDGE
INDICATOR
NEGATIVE
24 VAC
24 VAC
2
3 4
1
1 2
TX
RX
NC
PH2
2
3 4
1
1 2
TX
RX
PH1
GND
_
12/24
AC/DC
GND
_ 12/24
AC/DC
COM OUT
GND
_ 12/24
AC/DC
GND
_ 12/24
AC/DC
COM OUT
NC
POWER
POWER SUPPLY
SUPPLY
N
T1,6A
L
230Vac
50/60Hz
COM
LED
FLASH
STOP
STOP
PH2
PH1
OPEN
CLOSE
PAR
SBS
PH2 PH1
SHIELD
UP
MENU
SBS
DOWN
(RADIO)
ANT
NEG
ENC
V +
M -
M +
BATTERY
LS 1
LS 2
KEY
COM
CONNECTOR SAFETY AND CONTROL DEVICE
COM
Common for the FLASH-IND-LED inputs
FLASH
Flashing light output 24Vdc (without regulation), maximum 25W
IND
IND output for gate open indicator light 24 Vdc not regulated 4W MAX / Electric lock output 12Vac, 15VA maximum
selectable with parameter
IN
.
D
.
LED
Courtesy light output 24Vdc (without regulation), maximum 25W, controllable also via radio ON-OFF command (radio
channel 4 selecting
fC
.
y
. = 2,
tC
.
y
. = 0)
24 VAC
Accessories power supply 24 Vac without regulation, 200 mA (with battery operation output not active)
24 VAC
Accessories power supply 24 Vac without regulation, 200 mA (with battery operation output not active)
NEG
Accessories power supply negative
PH-POW
Photocells PH1 and PH2 power supply positive; phototest can be selected with parameter
tp
.
h
.
24 Vdc, 250 mA
STOP
STOP safety device, NC contact between STOP and STOP (warning, with dip switch 1 ON the safety device input is
off). This input is classified as a safety device; the contact can be deactivated at any time, cutting out the automation
system and disabling all functions, including Automatic Closure. Safety sensor edge, ON/OFF, NC contact or resistive
8K2 between STOP and STOP. Input selectable with parameter
Ed
.
m
.
PH2
Photocells (opening), NC contact between PH2 and COM (warning, with dip switch 2 ON the PHOTOCELL 2 safety
device input is off). The photocell is tripped at any time during opening of the automation system, halting operation
immediately; the automation system will continue opening when the contact is restored. In the event of intervention on
closure (parameter
Ph
.
2
. = 0) the device stops and on release re-opens.
PH1
Photocells (closing), NC contact between PH1 and COM (warning, with dip switch 3 ON the PHOTOCELL 1 safety
device input is off) The photocell is tripped at any time during closing of the automation system, halting operation
immediately and reversing the travel direction.
OPEN
OPEN command NO contact between OPEN and COM
Contact for the HOLD-TO-RUN function. The gate OPENS as long as the contact is held down
CLOSE
CLOSE command NO contact between CLOSE and COM
Contact for the HOLD-TO-RUN function. The gate CLOSES as long as the contact is held down
PAR
PARCIAL command NO contact between PAR and COM
Used to open the gate partially, depending on the software setting (not active in barrier/up-and-over mode)
SBS
STEPPING command NO contact between SBS and COM
Open/Stop/Close/Stop command, or as set in the software
COM
Common for the PH2-PH1-OPEN-CLOSE-PAR-SBS inputs
SHIELD
Antenna - shield -
ANT
Antenna - signal -
MESSAGES MEANING
--
Gate closed or switch-on after shutdown
OP
Gate opening
CL
Gate closing
SO
Gate stopped during opening
SC
Gate stopped during closure
4.2 - Display during normal operation
In “NORMAL OPERATING MODE”, i.e. when the system is powered up normally, the 3-figure LCD display shows the following status messages: