45
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-390
11. QT
1) Set panel tuning mode
Power meter Panel
ANT
Panel
Top1/
0.75kHz
±
0.05kHz
deviation
CH No. : 3
Deviation
Top2
adjustment
Signalling No. : 1
meter
(wide)
MIC input : OFF
Oscilloscope
Select QTDV
✽ ✽ ✽
in panel tuning mode
AG
Side
Universal
Deviation meter filter setting
AF VTVM
LPF : 3kHz
HPF : 50Hz
De-emphasis : 750
µ
s
PTT : ON
12. QT
1) Set panel tuning mode
0.375kHz
±
0.05kHz
deviation
CH No. : 3
adjustment
Signalling No. : 1
(narrow)
MIC input : OFF
Select QTDV
✽ ✽ ✽
in panel tuning mode
Turn the toggle SW to the
right (narrow)
Deviation meter filter setting
LPF : 3kHz
HPF : 50Hz
De-emphasis : 750
µ
s
PTT : ON
13. DQT
1) Set panel test mode
0.75kHz
±
0.05kHz
deviation
CH No. : 3
adjustment
Signalling No. : 1
(wide)
Select DQDV
✽ ✽ ✽
in panel tuning mode
Deviation meter filter setting
LPF : 3kHz
HPF : OFF
PTT : ON
14. DQT
1) Set panel tuning mode
0.375kHz
±
0.05kHz
deviation
CH No. : 3
adjustment
Signalling No. : 1
(narrow)
Select DQDV
✽ ✽ ✽
in panel tuning mode
Turn the toggle SW to the
right (narrow)
Deviation meter filter setting
LPF : 3kHz
HPF : OFF
PTT : ON
15. DTMF
1) Set panel test mode
3.0kHz
±
50Hz
deviation
CH No. : 3
adjustment
Signalling No. : 1
(wide)
Select DTDV
✽ ✽ ✽
in tuning mode
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON