47
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-390
1. AF level
1) Set panel test mode
SSG
Panel
ANT
Check
0.63V
±
0.3V
check
CH No. : 3
3% or less
Signalling No. : 1
AF VTVM
Side
Universal
SSG freq. : Each freq.
Oscilloscope
output : –53dBm/501
µ
V
Distortion
MOD. : 1kHz
meter
DEV. : 3kHz
Audio
2) Turn the toggle SW to the
analyzer
0.63V
±
0.3V
right (narrow)
5% or less
SSG freq. : Each freq.
output : –53dBm/501
µ
V
MOD. : 1kHz
DEV. : 1.5kHz
2. Hum and
1) Set panel test mode
42dB or more
noise ratio
CH No. : 3
check
Signalling No. : 1
SSG output : –53dBm/501
µ
V
2) Turn the toggle SW to the
37dBm
right (narrow)
SSG output : –53dBm/501
µ
V
3. BPF coil
1) Set panel test mode
Tracking
Panel
ANT
TX-RX
L205
Adjust the BPF coil so that the waveform is peaked.
CH No. : 2
generator
L210
The frequency with the peak waveform does not
Use this
Connect the spectrum
have to be the center frequency.
adjustment
analyzer to TP3.
Spectrum
TX-RX
TP3
After finished peaking the waveform, perform a
procedure
Signalling No. : 1
analyzer
3 point adjustment and set for maximum sensitivity.
after replace-
Push Orange to 3 point
ing any of
adjustment mode
the BPF
Select SNS
25
coils
L
22. BATT
1) Set panel test mode
Power meter Panel
ANT
Check
Cannot transmit
detection
CH No. : 3
LED (TX) blinks
check
Signalling No. : 1
DC VTVM Bottom BATT
BATT terminal voltage : 5.3V
terminal
PTT : ON
2) BATT terminal voltage : 6.5V
Transmit
PTT : ON
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
RX BPF 0-10
REF –10.0dBm
10dB/
ATT 10dB
A write B blank
RBW
300kHz
VBW
10kHz
SWP
70ms
SPAN 100.0MHz
TG LEVEL
–30dBm
Hi
Center
Low
MKR
–31.07dBm
Receiver Section