13
TK-390
• Operation
1. Select the setting value with the [Top 1] [Top 2] keys.
2. Press the [PTT] and the selected value is backed up and
operation shifts to the next item for setting.
3. Press [Side 2] on the Group selection screen in order to
return to Self programming mode.
• Note
1. Different sample displays are shown.
2. Setting item No.s are displayed with a 7-segment 2-digit
figure on the LCD.
3. Self programming mode cannot be set when set to
Disaable with the FPU.
4. A red LED lights up during TX frequency and TX signal-
ling.
5. Press [Orange] on the TX, RX frequencies setting screen
in order to clear in the channel frequencies data.
6. Press [Orange] on the signalling setting screen in order to
change or off the signalling function.
7. Flipping [Toggle] to the right during setting of RX, TX fre-
quencies and performing Up/Down operation allows fre-
quencies to be changed in MHz steps.
8. The RX and TX frequencies can be entered with the num-
ber pad keys.
• Flow Chart
3-3. Group Setting Mode
Set data for each Group while in this mode. After first
entering Self programming mode, select the “GROUP” dis-
play with [Top 1] [Top 2] and press [PTT] to set Group Set-
ting mode. Once in Group Setting mode, select the group
that needs setting with the [Top 1] [Top 2] keys and press
[PTT]. Next select the channel for setting with the [Top 1]
[Top 2] keys and press [PTT]. The setting items and setting
data will then appear so reset the data with the [Top 1]
[Top 2] keys and press [PTT]. When finished, the display
shifts to the next setting item. After finished setting all
items press [PTT] to return to next Group selection.
No.
Function name
Display
Remarks
Select Group
GRP 1
1~160
1
Battery save
BATT L
OFF, Short, Mid, Long
2
Time out timer
TOT 60
OFF, 30s~300s (30s step)
3
TOT pre alert
TOT.P 10
OFF, 1s~10s (1s step)
4
TOT rekey time
TOT.K 2
OFF, 1s~60s (1s setp)
5
TOT reset time
TOT.S 2
OFF, 1s~15s (1s step)
6
Group Delete/Add
D/A ADD
Delete, Add
7
Signalling
SIG AND
AND, OR
• Operation
1. Select the setting value with the [Top 1] [Top 2] keys.
2. Press the [PTT] and the selected value is backed up and
operation shifts to the next item for setting.
3. Press [Side 2] on the Group selection screen in order to
return to the Self programming mode initial display.
• Note
1. Different sample displays are shown.
2. Setting item No.s are displayed with a 7-segment 2-digit
figure on the LCD.
3. Self programming mode cannot be set when set to Dis-
able with the FPU.
• Flow Chart
Self programming mode
Channel setting mode
Group selection
Channel selection
1. RX frequency
2. RX signalling
3. TX frequency
4. TX signalling
5. Option signalling
6. Scan Delete/Add
7. Wide/Narrow
8. PTT ID on/off
9. TX power Hi/Low
10. Busy channel lockout on/off
11. Beat shift on/off
[Top 1] [Top 2]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
Orange
Orange
Orange
Orange
Orange
OFF
DQT I
DQT N
QT
Orange
Orange
Orange
Orange
Orange
OFF
DQT I
DQT N
QT
REALIGNMENT
Self programming mode
Group setting mode
Group selection
1. Battery save
2. Time out timer (TOT)
3. TOT pre-alert
4. TOT rekey time
5. TOT reset time
6. Scan group Delete/Add
7. Signalling AND/OR
[Top 1] [Top 2]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]