ADJUSTMENT
Panel Test Mode
This mode is used for making transceiver connection
tests and clearing the memory.
To set Panel test mode, turn on the power with [Side 2]
and [PTT] are still held down and then first release [PTT].
This mode cannot be set when disabled with the FPU.
In Panel test mode, when channel or signalling is se-
lected, the signalling that was most recently used is dis-
played.
Key operations in Panel test mode are as follows.
[Selector switch] : Use to select the test channel.
[PTT]
: For transmit.
[Top 1]
: For down signalling.
[Top 2]
: For up signalling.
[Side 1]
: For setting Panel tuning mode.
[Side 2]
: For switching power between Hi/Low.
Enter the LCD all lamp mode if held
down for 2 seconds.
[Orange]
: For monitoring.
[Toggle]
: For switching between Wide/Narrow.
Frequency (MHz)
CH
RX
TX
1
470.1000 (Center)
470.0000 (Center)
2
450.1000 (Low)
450.0000 (Low)
3
489.9000 (Hi)
489.9750 (Hi)
4
470.0000
470.0000
5
470.2000
470.2000
6
470.4000
470.4000
Signalling
No.
Encode tone
Decode tone
1
None
None
2
QT 67.0Hz
QT 67.0Hz
3
QT 250.3Hz
QT 25.03Hz
4
DQT 023N
DQT 023N
5
None
2 tone 321.7/928.1Hz
6
DTMF (9)
DTMF (159)
7
MSK PN pattern
None
8
100Hz square wave
None
9
Single tone 1633Hz
None
Channel
Signalling
• LCD all lamp mode
• Clear function
Pressing [PTT] while holding down [Orange] in Panel test
mode, triggers the clear function which clears all transceiver
data settings.
• Panel tuning mode
Press [Side 1] in Panel test mode to set Panel tuning
mode.
Note :
Different sample displays are shown.
Panel test mode
LCD all lamp mode
[Side 2]
holding about 2 sec.
[Side 2]
[Orange]
[Side 1]
Battery level
Squelch tight
[Side 2]
[Orange]
[Side 2]
Varicap shift voltage (Mid)
Varicap shift voltage (High)
Voltage change frequency (Low-Mid)
Voltage change frequency (Low-Mid)
Voltage change frequency (Mid-High)
Voltage change frequency (Mid-High)
Frequency tune
RF high power
RF low power
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[PTT]
[Orange] : Write data
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Orange]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
[Side 2]
VSWM 73
VCO –3V adj.
VSWH145
VCO –6V adj.
464.000 VCO –3V shift RX frequency
464.000 VCO –3V shift TX frequency
VCO –6V shift RX frequency
VCO –6V shift TX frequency
479.000
479.000
FREQ 140
TX frequency adj.
POW 100
[Orange]
RF high power (Low)
POW 100
L
High power adj. (Low edge)
RF high power (Cen)
POW 100
C
High power adj. (Center)
RF high power (Hi)
POW 100
H
POW 50
LO
High power adj. (Hi edge)
Low power adj.
Function name
Display
Remarks
Max deviation
[Side 2]
[Side 2]
MDV 60
[Orange]
Max deviation (Low)
MDV 90
L
Deviation adj. (Low edge)
Max deviation (Cen)
MDV 62
C
Deviation adj. (Center)
Max deviation (Hi)
MDV 44
H
Deviation adj. (Hi edge)
Deviation balance
BLNC125
QT deviation
QTDV150
DQT deviation
DQDV117
DTMF deviation
DTDV165
MSK deviation
MSDV100
SQ T255
Sensitivity
SNS 70
MON
SQ O 87
Squelch open
BATT– – –
BATT150
END
[Side 2]
[Side 2]
[Orange]
Sensitivity (Low)
SNS 15
L MON
Sensitivity adj. (Low edge)
Sensitivity (Cen)
SNS 70
C MON
Sensitivity adj. (Center)
Sensitivity (Hi)
SNS 200
H MON
Sensitivity adj. (Hi edge)