ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
46
TK-390
16. DTMF
1) Set panel tuning mode
Power meter Panel
ANT
Panel
Top1/
1.5kHz
±
50Hz
deviation
CH No. : 3
Deviation
Top2
adjustment
Signalling No. : 1
meter
(narrow)
Select DTDV
✽ ✽ ✽
Oscilloscope
in panel tuning mode
Turn the toggle SW to the
AG
Side
Universal
right (narrow)
AF VTVM
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
17. MSK
1) Set panel test mode
3.00kHz
±
50Hz
deviation
CH No. : 3
adjustment
Signalling No. : 1
(wide)
Select MSDV
✽ ✽ ✽
in panel tuning mode
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
18. MSK
1) Set panel tuning mode
1.50kHz
±
50Hz
deviation
CH No. : 3
adjustment
Signalling No. : 1
(narrow)
Select MSDV
✽ ✽ ✽
in panel tuning mode
Turn the toggle SW to the
right (narrow)
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
19. Transmission 1) Set panel test mode
Check
42dB or more
S/N check
CH No. : 3
(wide)
Signalling No. : 1
Deviation meter filter setting
LPF : 300Hz
HPF : 3kHz
De-emphasis : 750
µ
s
PTT : ON
20. Transmission 1) Set panel test mode
37dB or more
S/N check
CH No. : 3
(narrow)
Signalling No. : 1
Turn the toggle SW to the
right (narrow)
Deviation meter filter setting
LPF : 300Hz
HPF : 3kHz
De-emphasis : 750
µ
s
PTT : ON
21. BATT
1) Set panel test mode
Power meter Panel
ANT
Side
Orange Write the voltage
6.2V
detection
CH No. : 3
level
writing
Signalling No. : 1
DC VTVM Bottom BATT
Select BATT
✽ ✽ ✽
terminal
in panel tuning mode
PTT : ON