(No.RA054<Rev.001>)1-49
9.
DMR High
Deviation
1) Adj item:
[D DDEV]
Adjust: [****]
2) Adj item:
[L1]
→
[L3]
→
[C2]
→
[H1]
→
[H3]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[DMR High
Deviation (DMR
Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Write fixed value for
each adjustment point.
(The value is written
below.)
Transmit at each
adjustment point and
check that the Analog
deviation is between
2695Hz and 2803Hz.
Deviation meter
LPF: 3kHz
HPF: OFF
500(Reference value)
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
2695~2803Hz
10. QT
Deviation
[Analog
Wide]
1) Adj item:
[Aw QT]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[C2]
→
[H1]
→
[H3]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[QT Deviation
(Analog Wide)]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write the value as
followings.
512 (Reference value)
0.75kHz±0.05
kHz
[Analog
Narrow]
1) Adj item:
[An QT]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[C2]
→
[H1]
→
[H3]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[QT Deviation
(Analog Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write the value as
followings.
512 (Reference value)
0.35kHz±0.05
kHz
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
Panel tuning
mode
PC test mode
Test-
equipment
Unit Terminal Unit
Parts
Method