1-134 (No.RA054<Rev.001>)
[Analog
Narrow]
1) Adj item:
[An ADEV]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[L5]
→
[C1]
→
[C3]
→
[C5]
→
[H2]
→
[H4]
→
[H6]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[Maxmum
Deviation (Analog
Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Low5]
→
[Center1]
→
[Center3]
→
[Center5]
→
[High2]
→
[High4]
→
[High6]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write fixed value for
each adjustment point.
(The value is written
below.) Transmit at
each adjustment point
and check that the
deviation is between
2050Hz and 2150Hz.
Deviation meter
LPF: 15kHz
HPF: OFF
493(Reference value)
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
2050~2150Hz
7. NXDN
High
Deviation
[NXDN
Narrow]
1) Adj item:
[Nn NDEV]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[L5]
→
[C1]
→
[C3]
→
[C5]
→
[H2]
→
[H4]
→
[H6]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[NXDN High
Deviation (NXDN
Narrow]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Low5]
→
[Center1]
→
[Center3]
→
[Center5]
→
[High2]
→
[High4]
→
[High6]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write fixed value for
each adjustment point.
(The value is written
below.) Transmit at
each adjustment point
and check that the
Analog deviation is
between 2995Hz and
3117Hz.
Deviation meter
LPF: 3kHz
HPF: OFF
498(Reference value)
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
2995~3117Hz
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
Panel tuning
mode
PC test mode
Test-
equipment
Unit Terminal Unit
Parts
Method