(No.RA054<Rev.001>)1-133
6.
Maximum
Deviation
[Analog
Wide 5k]
1) Adj item:
[Aw ADEV]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[L5]
→
[C1]
→
[C3]
→
[C5]
→
[H2V]
→
[H4]
→
[H6]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[Maxmum
Deviation (Analog
Wide 5k)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Low5]
→
[Center1]
→
[Center3]
→
[Center5]
→
[High2]
→
[High4]
→
[High6]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write fixed value for
each adjustment point.
(The value is written
below.) Transmit at
each adjustment point
and check that the
deviation is between
4150Hz and 4250Hz.
Deviation meter
LPF: 15kHz
HPF: OFF
496(Reference value)
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
4150~4250Hz
[Analog
Wide 4k]
1) Adj item:
[As ADEV]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[L5]
→
[C1]
→
[C3]
→
[C5]
→
[H2V]
→
[H4]
→
[H6]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[Maxmum
Deviation (Analog
Wide 4k)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Low5]
→
[Center1]
→
[Center3]
→
[Center5]
→
[High2]
→
[High4]
→
[High6]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write fixed value for
each adjustment point.
(The value is written
below.) Transmit at
each adjustment point
and check that the
deviation is between
3310Hz and 3410Hz.
Deviation meter
LPF: 15kHz
HPF: OFF
496(Reference value)
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
3310~3410Hz
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
Panel tuning
mode
PC test mode
Test-
equipment
Unit Terminal Unit
Parts
Method