(No.RA054<Rev.001>)1-51
[Analog
Narrow]
1) Adj item:
[An LTR]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[C2]
→
[H1]
→
[H3]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[LTR Deviation
(Analog Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write the value as
followings.
512 (Reference value)
0.75kHz±0.05
kHz
13. DTMF
Deviation
[Analog
Wide]
1) Adj item:
[Aw DTMF]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[C2]
→
[H1]
→
[H3]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[DTMF Deviation
(Analog Wide)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write the value as
followings.
555 (Reference value)
2.50kHz±0.05
kHz
[Analog
Narrow]
1) Adj item:
[An DTMF]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[C2]
→
[H1]
→
[H3]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[DTMF Deviation
(Analog Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write the value as
followings.
555 (Reference value)
1.25kHz±0.05
kHz
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
Panel tuning
mode
PC test mode
Test-
equipment
Unit Terminal Unit
Parts
Method