3-12
Setup and Installation
Installing Cable Shielding
To shield cabling for your PIO-SSR Series board, perform the
following steps:
1. With cabling installed and clamped, wrap all cables together with a
piece of tape to mark a shield boundary at a point
½
-inch or more
away from the inside surface of the mounting plate, as shown in
Figure 3-7.
Figure 3-7. Cabling Taped to Show Shield Boundary
2. Remove the two clamp-adjusting screws and the clamp from the
board’s mounting plate.
3. Unplug the cable connectors from the board, and pull the taped
cabling back through the mounting plate until the tape marker is
beyond the clamping area.
4. Beginning at the tape marker, cover the cabling with a single piece of
jacket to the desired length, as shown in Figure 3-8.
Figure 3-8. Cabling Wrapped with Jacket to Tape Boundary
5. Remove tape from cabling, and use scissors to cut
½
-inch flaps in the
jacket on both sides of cable, as shown in Figure 3-9.
PIO-SSR-48
Tape Marker
½
inch
from Mounting Plate
Mounting Plate
PIO-SSR-48
Mounting Plate
Tape
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com