• BEFORE OPERATING THIS FRYER, CHECK PIPE 
JOINTS FOR LEAKS BY USING A SOAP AND WATER 
SOLUTION ONLY. DO NOT USE AN OPEN FLAME!

ON AN AA OR CMG (MILLIVOLT) FRYER, DO NOT 
SHORT GAS VALVE TERMINALS WHEN TESTING 
WIRING AS THERMOSTAT AND GAS VALVE DAMAGE 
MAY OCCUR AND CAUSE UNSAFE CONDITIONS.

Pipe joint compounds that are used on threaded joints 
of appliance piping shall be resistant to the action of 
liquefi ed petroleum gases (Loctite PST 56765). When 
using pipe joint compound do not apply to the fi rst two 
threads. Use only very small amount and only on male 
threads. This will prevent clogging of burner orifi ces 
and the gas valve. Never use compound on female 
threads as it might be pushed into the gas valve.

Have your installer check for gas leaks using a soap 
and water solution before operating. DO NOT USE AN 
OPEN FLAME TO CHECK FOR GAS LEAKS.

1) The Keating Gas Fryer and its individual shut off 
valves must be disconnected from the gas supply pip-
ing system during any pressure testing of that system 
at test pressures in excess of 1/2 psi (3.45kPa) 
(13.84 in WC) High pressure can damage the gas 
valve causing a hazardous condition.

2.) The appliance must be isolated from the gas 
supply piping system by closing its individual manual 
shutoff valve during any pressure testing of the gas 
supply piping system at test pressures equal to or 
less than 1/2 psi (3.45 kPa).

NOTE:

 If more than one gas fryer is on the same sup-

ply line, you may require a larger line. Consult your 
local gas company to assure adequate volume and 
pressure. Refer to serial plate for proper gas require-
ments for your particular model.

NOTE:

 Piping for a battery should be at least 1-1/4" 

to 1-1/2" IPS, depending on total BTU input. Consult 
your local gas supplier for appropriate battery piping 
size.

Never leave your fryer operating unattended.

 

(When all previous instructions have been completed).

Check the serial plate on the panel (inside cabinet) to 
determine if the burner is set up for the proper type 
gas before connecting the quick-disconnect or piping 
from the building gas supply pipe.

a. Maximum incoming gas pressure 

   NATURAL GAS – 7 inches W.C. with burners on

   LP GAS – 11 inches W.C. with burners on

If a popping noise is heard from the fryer during the 
cooking cycle, the following checks must be made in 
this order:

b. Fryer manifold gas pressure   

 

 

    NATURAL GAS – 4 inches W.C. with burners on

    LP – 10 inches W.C. with burners on

ALWAYS disconnect fuel source and power supply 
before servicing.

NEVER move a fryer when full of oil.

NEVER introduce objects or liquids into fryer, while 
operational, which are not designed or made for 
cooking.

THIS FRYER MAY NOT BE ALTERED, MODIFIED OR 
CHANGED IN ANY WAY.

GAS LEAK TESTING

Prior to lighting your fryer:

1. Make sure all thermostats, switches and safety 
    valves are in the “OFF” position.

2. Turn main On/Off manual gas valve to the “ON”
    position.

3. Have your plumber or gas company check for 
    leaks with a soap solution or sniffer. 
    (NEVER check with an open fl ame!)

4. Have your plumber or gas company 
    representative light the constant pilot. 
    (Not necessary if your fryer has a spark ignitor.)

GAS PRESSURE AT MANIFOLD

      

NATURAL Gas - 4.0 in. W.C.

      LP Gas - 10.0 in. W.C.

MINIMUM INCOMING GAS PRESSURE

      

NATURAL Gas - 7.0 in. W.C.

      LP Gas - 11.0 in. W.C.

NOTE: 

It is estimated that half of all service calls 

made on Keating Instant Recovery® Fryer result from 
an inadequate gas supply. During installation, have 
a gas company representative make certain that the 
fryer is receiving adequate gas pressure and volume 
(see “Installation” or your serial plate on the fryer 
door).

PROPANE GAS MAY EVENTUALLY LOSE ITS ODOR 
AND PRECAUTIONS SHOULD BE TAKEN TO ASSURE 
THAT IT IS NOT PRESENT EVEN THOUGH YOU DO 
NOT DETECT AN ODOR. IF THERE IS ANY DOUBT, 
YOU SHOULD CALL YOUR LOCAL PROPANE GAS 
SUPPLIER FOR ASSISTANCE.

Содержание Instant Recovery 2000 Series

Страница 1: ......

Страница 2: ...ACTURER S INSTRUCTIONS THIS PRODUCT COULD EXPOSE YOU TO SUBSTANCES IN FUEL OR IN FUEL COMBUSTION WHICH CAN CAUSE DEATH OR SERIOUS ILLNESS AND WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER...

Страница 3: ...tions of any kind to your equipment will void the warranty Before uncrating check equipment carefully for damage IF EQUIPMENT ARRIVES DAMAGED Keating does not assume responsibility for loss or damage...

Страница 4: ...portant consider ations for efficient operation of the Keating Gas Fryer It should be installed so that the products of combus tion are removed efficiently without producing drafts that will interfere...

Страница 5: ...STERS IT MUST BE INSTALLED WITH CASTERS SUPPLIED A CONNECTOR COMPLYING WITH EITHER ANSI Z21 69 OR CAN CGA 6 16 AND A QUICK DIS CONNECT DEVICE COMPLYING WITH EITHER ANSI Z21 41 OR CSA 6 9 IT MUST ALSO...

Страница 6: ...leave your fryer operating unattended When all previous instructions have been completed Check the serial plate on the panel inside cabinet to determine if the burner is set up for the proper type gas...

Страница 7: ...E SWITCHING THE FRYER ON IF OIL LEVEL DROPS BELOW TOP OF HEAT TRANSFER TUBES SEVERE DAMAGE TO FRYER AND INJURY TO OPERATOR MAY RESULT WATER IN ANY FORM AND HOT OIL DON T MIX OIL EXPANDS WHEN HEATED TH...

Страница 8: ...he OFF position 2 Turn MAIN POWER switch to the OFF position 3 Turn gas valve knob to the OFF position 4 Turn gas supply valve to the OFF position 5 Check to make sure all burners and pilot are out BB...

Страница 9: ...designed to provide maximum production efficiency and deliver high quality food products Low temperature cooking highly polished stainless steel and a true COLD ZONE mean extended oil life Follow the...

Страница 10: ...show StO for ap proximately two seconds and the timer will return to normal operation Repeat the process as necessary for the other timers OPERATING LOGIC When the timer is powered up the display will...

Страница 11: ...CLE CLEANING AND BOIL OUT FOR A SINGLE FRYER When cleaning and boiling out your fryer use Keating Sea Powder and Keating Klenzer to keep your fryer in top condition Keating Sea Powder dissolves any gr...

Страница 12: ...ETTING MOTOR TO PREVENT SERIOUS INJURY WHEN RESET SWITCH IS ENGAGED SEE FILTER MANUAL 16 Check thermostat bulb positioning see page 12 17 Refill the fryer with new or filtered oil FOR A FRYER WITH ATT...

Страница 13: ...d damaging the fryer do not power wash spray or hose it down while cleaning it 17 Pump must be primed with oil after boil out with water FAILURE TO LUBRICATE PUMP MAY CAUSE SEVERE DAMAGE TO FILTER SYS...

Страница 14: ...meter in same position for every calibration 4 If calibration of fryer is found to be less than 25 F off simply loosen four dial plate retaining screws rotate dial plate to match thermometer reading a...

Страница 15: ...pression fitting snugly into fryer vessel 5 Adjust bulb so at least 2 of bent portion of it is next to heat transfer tube and tighten compression nut onto compression fitting for fryer 10x11 18 up The...

Страница 16: ...uct overloaded in fryer vessel c Oil is breaking down and foaming d Water in cold zone a Fill fryer up to Fill Level line as oil expands when heated b Follow recommended cooking production figures in...

Страница 17: ...plates are damaged or lost replace them immediately B C A D E BACK PANEL F PARTS LIST GAS FRYER CONTROL PANEL AA GAS ITEM QTY DESCRIPTION P N A 1 THERMOSTAT DIAL PLATE 375 058037 B 1 THERMOSTAT KNOB...

Страница 18: ...CKER WHITE MOMENTARY 032297 Push to Light Hi Limit Test G 1 SWITCH MELT IDLE FRY 032829 H 1 INDICATING LIGHT GREEN 021255 I 1 INDICATING LIGHT RED 021209 J 1 HIGH LIMIT Resettable 034357 K 1 FLAME SWI...

Страница 19: ...016341 E 1 RUNNER PILOT TUBE ASSEMBLY 019408 F 1 GAS VALVE NATURAL 023625 LP 023624 POT ASSEMBLY 14AA GAS F A B C D E ITEM QTY DESCRIPTION P N A 3 3 FIN RADIANT 000041 B 1 POT WELDMENT 14 GAS UNI POT...

Страница 20: ...F 1 GAS VALVE NATURAL Front Drain TS 037237 LP Front Drain TS 037238 NATURAL Rear Drain TS 037241 1 LP Rear Drain TS 037242 1 NATURAL All BB Models 037227 1 LP All BB Models 037228 ITEM QTY DESCRIPTIO...

Страница 21: ...1 800 KEATING GAS FRYER SERIES 2000 19 WIRING DIAGRAMS AA 2000 ELECTRICAL ASSEMBLY BB 2000 ELECTRICAL ASSEMBLY...

Страница 22: ...keatingofchicago com 20 TS 2000 ELECTRICAL ASSEMBLY not shown to scale BB ELECTRICAL ASSEMBLY WITH SAFE AND EASY FILTER not shown to scale...

Страница 23: ...1 800 KEATING GAS FRYER SERIES 2000 21 TS ELECTRICAL ASSEMBLY WITH SAFE EASY FILTER BASKET LIFT ELECTRICAL ASSEMBLY ALL FRYERS...

Страница 24: ...nty against latent defects Exclusions The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installation or main...

Страница 25: ...RANTY CARD ON OUR WEBSITE FOR YOUR CONVENIENCE COMPANY ADDRESS CITY STATE ZIP CODE DEALER NAME DATE OF PURCHASE INVOICE SERIAL MODEL I HAVE READ THE INSTALLATION AND OPERATING INSTRUCTIONS SIGNED DATE...

Отзывы: