PREVENTATIVE MAINTENANCE CHART 

TIME FRAME

OPERATOR/OWNER

AT LEAST 

DAILY*

• Check lights and controls.

• Check that the oil is up to 
   “Fill Level” line.

• Clean all baskets.

• Drain, strain or fi lter oil.

AT LEAST 

WEEKLY*

• Drain and clean fryer.

• Boil-out fryer.

AT LEAST 

MONTHLY*

• Verify Thermostat settings.

• Test Hi-Limit control.

TIME FRAME

QUALIFIED SERVICE PERSONNEL

AT LEAST 

YEARLY*

• Check burner fl ame color and 
   adjust air shutters.
• Disassemble fryer to clean pilot 
   and burner orifi ces and runner 
   pilot tube.
• Check and replace radiants.
• Calibrate thermostat.

*

High production facilities should be checked more often.

Contact the factory or a local service company to perform
maintenance and repairs.

HI-LIMIT CHECK BI-MONTHLY

The manual Hi-Limit test button can be used to test 
the Hi-Limit Control by pushing and holding the but-
ton in until the fryer reaches the Hi-Limit temperature  
(425°F). Place an accurate thermometer in the oil. If 
the Hi-Limit Control doesn’t shut off the fryer between 
425°F and 450°F, have it replaced.

LIMITED CALIBRATION

(Less than 25° difference)

You will need: 

   One screwdriver with 1/8" wide fl at blade

   One accurate fryer thermometer

Figure 6

1. Set thermostat to desired frying temperature.

2. Allow thermostat to cycle three times.

3. Place an accurate thermometer in the oil at the 
tip of the thermostat bulb. Left front corner of fryer 
vessel at the High Limit Bulb is recommended.

NOTE: 

Locate thermometer in same position for 

every calibration.

4. If calibration of fryer is found to be less than 25°F 
off, simply loosen four dial plate retaining screws, 
rotate dial plate to match thermometer reading and 
tighten screws. If it is more than 25°F off contact a 
qualifi ed service company.

DO NOT ADJUST THE THERMOSTAT SET SCREW - IT 
VOIDS ANY WARRANTY ON PART.

THERMOSTAT BULB POSITIONING 

BEFORE REPLACING, TEST THERMOSTATS

NOTE: Operational problems can easily be corrected 
by thermostat bulb positioning.

 

Keating’s patented thermostat application is accurate 
within 2°F of the dial setting between 250°F – 350°F. 
This accuracy is attained only if the thermostat bulb 
is placed properly against the heat transfer tube. To 
quickly and accurately test for proper bulb placement, 
a single thickness of writing paper should be pulled 
through between the tube and the bulb with medium 
resistance.

*

1. *

For 14" Gas Fryers:

 

    • The end of thermostat bulb should touch the
       burner tube.

2. 

For 10x11", 18" & Up Gas Fryers:

 

    • If the bulb is too loose, the paper will slip 
       through with little or no resistance. A fryer with 
       a thermostat bulb that is too loose will 
       overshoot.

       

Overshoot:

 The thermostat takes a long time 

       to cycle and then misses its preset temperature 
       by 20°F - 40°F yielding a poor quality product. 

    • If the bulb is too tight, the paper will either not 
       pull through or it will tear. A fryer with a 
       thermostat bulb that is too tight will short cycle.

       

Short Cycle:

 The thermostat will cycle rapidly 

       while the fryer is in the idle mode; the 
       temperature will be erratic.

Thermostat knob 
removed to reveal 
calibration screws

Thermostat Bulb 
Positioning 10x11, 
18 & Up

Содержание Instant Recovery 2000 Series

Страница 1: ......

Страница 2: ...ACTURER S INSTRUCTIONS THIS PRODUCT COULD EXPOSE YOU TO SUBSTANCES IN FUEL OR IN FUEL COMBUSTION WHICH CAN CAUSE DEATH OR SERIOUS ILLNESS AND WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER...

Страница 3: ...tions of any kind to your equipment will void the warranty Before uncrating check equipment carefully for damage IF EQUIPMENT ARRIVES DAMAGED Keating does not assume responsibility for loss or damage...

Страница 4: ...portant consider ations for efficient operation of the Keating Gas Fryer It should be installed so that the products of combus tion are removed efficiently without producing drafts that will interfere...

Страница 5: ...STERS IT MUST BE INSTALLED WITH CASTERS SUPPLIED A CONNECTOR COMPLYING WITH EITHER ANSI Z21 69 OR CAN CGA 6 16 AND A QUICK DIS CONNECT DEVICE COMPLYING WITH EITHER ANSI Z21 41 OR CSA 6 9 IT MUST ALSO...

Страница 6: ...leave your fryer operating unattended When all previous instructions have been completed Check the serial plate on the panel inside cabinet to determine if the burner is set up for the proper type gas...

Страница 7: ...E SWITCHING THE FRYER ON IF OIL LEVEL DROPS BELOW TOP OF HEAT TRANSFER TUBES SEVERE DAMAGE TO FRYER AND INJURY TO OPERATOR MAY RESULT WATER IN ANY FORM AND HOT OIL DON T MIX OIL EXPANDS WHEN HEATED TH...

Страница 8: ...he OFF position 2 Turn MAIN POWER switch to the OFF position 3 Turn gas valve knob to the OFF position 4 Turn gas supply valve to the OFF position 5 Check to make sure all burners and pilot are out BB...

Страница 9: ...designed to provide maximum production efficiency and deliver high quality food products Low temperature cooking highly polished stainless steel and a true COLD ZONE mean extended oil life Follow the...

Страница 10: ...show StO for ap proximately two seconds and the timer will return to normal operation Repeat the process as necessary for the other timers OPERATING LOGIC When the timer is powered up the display will...

Страница 11: ...CLE CLEANING AND BOIL OUT FOR A SINGLE FRYER When cleaning and boiling out your fryer use Keating Sea Powder and Keating Klenzer to keep your fryer in top condition Keating Sea Powder dissolves any gr...

Страница 12: ...ETTING MOTOR TO PREVENT SERIOUS INJURY WHEN RESET SWITCH IS ENGAGED SEE FILTER MANUAL 16 Check thermostat bulb positioning see page 12 17 Refill the fryer with new or filtered oil FOR A FRYER WITH ATT...

Страница 13: ...d damaging the fryer do not power wash spray or hose it down while cleaning it 17 Pump must be primed with oil after boil out with water FAILURE TO LUBRICATE PUMP MAY CAUSE SEVERE DAMAGE TO FILTER SYS...

Страница 14: ...meter in same position for every calibration 4 If calibration of fryer is found to be less than 25 F off simply loosen four dial plate retaining screws rotate dial plate to match thermometer reading a...

Страница 15: ...pression fitting snugly into fryer vessel 5 Adjust bulb so at least 2 of bent portion of it is next to heat transfer tube and tighten compression nut onto compression fitting for fryer 10x11 18 up The...

Страница 16: ...uct overloaded in fryer vessel c Oil is breaking down and foaming d Water in cold zone a Fill fryer up to Fill Level line as oil expands when heated b Follow recommended cooking production figures in...

Страница 17: ...plates are damaged or lost replace them immediately B C A D E BACK PANEL F PARTS LIST GAS FRYER CONTROL PANEL AA GAS ITEM QTY DESCRIPTION P N A 1 THERMOSTAT DIAL PLATE 375 058037 B 1 THERMOSTAT KNOB...

Страница 18: ...CKER WHITE MOMENTARY 032297 Push to Light Hi Limit Test G 1 SWITCH MELT IDLE FRY 032829 H 1 INDICATING LIGHT GREEN 021255 I 1 INDICATING LIGHT RED 021209 J 1 HIGH LIMIT Resettable 034357 K 1 FLAME SWI...

Страница 19: ...016341 E 1 RUNNER PILOT TUBE ASSEMBLY 019408 F 1 GAS VALVE NATURAL 023625 LP 023624 POT ASSEMBLY 14AA GAS F A B C D E ITEM QTY DESCRIPTION P N A 3 3 FIN RADIANT 000041 B 1 POT WELDMENT 14 GAS UNI POT...

Страница 20: ...F 1 GAS VALVE NATURAL Front Drain TS 037237 LP Front Drain TS 037238 NATURAL Rear Drain TS 037241 1 LP Rear Drain TS 037242 1 NATURAL All BB Models 037227 1 LP All BB Models 037228 ITEM QTY DESCRIPTIO...

Страница 21: ...1 800 KEATING GAS FRYER SERIES 2000 19 WIRING DIAGRAMS AA 2000 ELECTRICAL ASSEMBLY BB 2000 ELECTRICAL ASSEMBLY...

Страница 22: ...keatingofchicago com 20 TS 2000 ELECTRICAL ASSEMBLY not shown to scale BB ELECTRICAL ASSEMBLY WITH SAFE AND EASY FILTER not shown to scale...