EN - 53
Positioned on menu 04
PAR
DESCRIPTION
DEFAULT
min
MAX
ALARMS
A01
Low temperature alarm differential (relative to the SetPoint)
-4°C
-50°C
0°C
A02
High temperature alarm differential (relative to the SetPoint)
8°C
0°C
50°C
A03
Temperature alarm delay from board switch-on or defrost end
90 min
0 min
300 min
A04
High or low temperature alarm delay
60 min
0 min
300 min
A05
Minimum evaporator temperature accepted relative to the SetPoint
-50°C
-50°C
0°C
A06
Maximum temperature of the condenser allowed
58°C
0°C
90°C
A07
Temperature differential for dirty condenser alarm
25°C
0°C
60°C
A08
Evaporator low temperature alarm delay 60min 0min 300min
60 min
0 min
300 min
DISPLAY
D01
Unit of measurement of the temperature (0 Celsius; 1 Fahrenheit)
0
0
1
D02
Cell probe offset
0
°C
-10
°C
10
°C
D03
BackLight (0=ON pressing a key; 1=always ON)
0
0
1
D05
Enables recorded alarm warning 1 0 1
1
0
1
DEFROSTING
S01
Type of defrosting start:
1: defrosting enabling from keyboard
2: defrosts every S04 functioning hours of the board
4: defrosts every S04 functioning hours of the compressor
8: defrosts after one hour from board switch-on
16: daily defrosting at H01, H02, H03 and H04
128: activates intelligent defrosting function
3
0
255
S02
S02 Defrosting end temperature
12°C
-10°C
30°C
S03
S03 Maximum duration of defrosting
30 min
1 min
300 min
S04
S04 Interval between two defrosting cycles
8 h
1 h
48 h
S05
Type of defrosting:
0: compressor stop
1: resistances
2: compressor cycle reverse with delay time S07
1
0
2
S06
S06 Dripping time
120 sec
0 sec
300 sec
S07
Compressor start-up delay for HotGas
60 sec
0 sec
300 sec
S08
Compressor functioning time for start of automatic defrosting
5 h
1 h
48 h
CONFIGURATION
C01
Door micro switch function
0: disabled
1: switches compressor, resistances and evap. fan off
2: switches just evap fan off
2
0
2
C02
Door micro switch polarity
1
0
1
C03
Open door maximum delay
4 min
0 min
30 min
C04
Enable buzzer: 0: Disabled 1: Enabled 2: Enabled from 06 to 24
2
0
2
C05
Light Management: 0: Parallel to the Door 1: AUX and from Door key
1
0
1
C07
Enable evaporator probe (0 disabled; 1 Enabled)
1
0
1
C08
Enable condenser probe (0 disabled; 1 Enabled)
1
0
1
C10
Enable high pressure digital input (0 disabled; 1 Enabled)
0
0
1
C11
High pressure digital input polarity
1
0
1
Password = 255