Menu 07
Stampa
alarm list
Stampa
faults list
The alarm appears if the evaporator has not managed to clean itself in the maximum time
envisioned. For example, it can happen if the door has remained open accidentally for a
period long enough or if the defrosting resistances are broken.
PERFORM MANUAL DEFROSTI NG AND CALL THE AFTER-SALES ASSI STANCE I F
THE PROBLEM PERSI STS.
I t appears if the temperature does not reach the set value set in the pre-established times.
CALL AFTER-SALES ASSI STANCE
The alarm appears if the cell probe is broken.
I n this case, the appliance will function according to the percentage of the work set. The
mask will remain active until the fault is repaired.
CALL AFTER-SALES ASSI STANCE
The alarm appears if the evaporator probe is broken. I n this case, only timed defrosting is
performed while "intelligent" defrosting is excluded. The mask will remain active until the
fault is repaired.
CALL AFTER-SALES ASSI STANCE
The alarm appears if the condenser probe is broken. I n this case, the condenser fan will
function in parallel with the compressor also in low temperatures. The mask will remain
active until the fault is repaired.
CALL AFTER-SALES ASSI STANCE
7.5. PRI NTER ( optional)
Position on:
Menu 07
By pressing the
ENTER
key, the program set is displayed.
By pressing the
or
key, select the type of print.
By pressing the
AUX
key for a prolonged period, the printer is started.
Daily Printout
The daily printout can be set via parameter PR2.
Other Printouts
In the Parameters Menu it is possible to launch the "parameters print" by pressing the
AUX
key for a prolonged period.
In the Cycle Test Data Menu it is possible to launch the "cycle test data print" by pressing the
AUX
key for a prolonged period.
Sampling
The recordings take place with an established sampling time per parameter.
Every recording saves the value of the Cell, Evaporator and Condenser probes (if present), the alarms present and
defrosting in progress. The memory can contain up to 3500 recordings. Once the space available has been
fi lled, the
new data overwrites the old data.
The start and end of an alarm and the start and end of defrosting are recorded.
AL Tim e Out Def
AL High T Room
AL Room Probe
AL Evap Probe
AL Cond Probe