EN - 21
Press the
ENTER
key to con
fi rm the language selected.
Completes the modi
fi cation of the values. Press the
MENU
key twice to exit the menu, or do not operate.
7.3.4 SCROLLI NG THE DI SPLAY
I t is possible to scroll the LCD , displaying the following masks:
By pressing the
ENTER
key,
scroll the different masks
on the display.
Press the
ENTER
key to display the current date and time.
By pressing the
ENTER
key, cell and evaporator temperature are displayed.
By pressing the
ENTER
key, condenser and evaporator temperature are displayed.
By pressing the
ENTER
key, display the state of the two outputs (1= on; 0= off).
C
= compressor
D
=
defrosting
FE
= evaporator fan
UR
= umidi
fi cator heater
L
= light
R
= heating heater
E
= extractor fan
By pressing the
ENTER
key, display the state of the digital outputs (1= on; 0= off).
BT1
=
door
BT2
= pressure switch
By pressing the
ENTER
key, go back to the main mask.
7.3.5 SETTI NG DATE AND TI ME
I mmediately after appliance switch-on or after a long shutdown period, it is fundamental to set the current time
and date. I n the event of a “black out” a buffer battery allows the autonomy of the clock for about 10 days.
Positioned on:
Menu 06
By pressing the
ENTER
key, date and time are displayed, thus allowing their modi
fi cation.
By pressing the
or
key, the value selected is increased or decreased.
By pressing the
ENTER
key, the value set is con
fi rmed and you pass to the next value.
Completes the modi
fi cation of the values. Press the
MENU
key twice to exit the menu,
or do not operate.
t 13 °C Ur 75%
14d
Ri 40%
f1
t 13 °C Ur 75%
14d
Ri 40%
f1
12/05/08
15:05:03
Cell
5.0 °C
Evap -3.0 °C
Conden 41.0 °C
Evap 2 Disab
C D FE FC L X A
1 0 0 1 0 0 0
BT1 BT2
0 0
Menu 08
set clock
Date:
00
/00/00
Time: 00:00:00
Date:
15
/00/00
Time: 00:00:00
Date: 15/05/07
Time: 14:22:46
C D FE UR L R E
1
0
0
1
0 0 0