KATflow 100
9 Specification
9 Specification
General
Measuring principle : Ultrasonic time difference
correlation principle
Flow velocity range : 0.01 ... 25 m/s
Resolution : 0.25 mm/s
Repeatibility : 0.15 % of measured value ± 0.015 m/s
Accuracy : ± 1 ... 3 % of measured value
depending on application,
± 0.5 % of measured value with
process calibration
Turn down ratio : 1/100
Gaseous and solid
content of liquid
media : < 10 % of volume
Flow transmitter
Enclosure : Wall or pipe mounted housing
Degree of protection : IP 66 according EN 60529
Operating temperature : -10 ... 60 °C (14 ... 140 °F)
Housing material : Die cast aluminium
Flow channels : 1
Power supply : 100 ... 240 V AC 50/60 Hz,
9 ... 36 V DC, specials upon request
Display : Optional LCD graphic display, 128 x 64 dots, backlit
Keypad : Optional four button internal keypad or programmer
Dimensions : H 120 x W 160 x D 80 mm without cable glands
Weight : Approx. 750g
Power consumption : < 5 W
Display damping : 0 ... 99 s
Measurement rate : 1Hz standard, higher rates on application
Response time : 1 s
Operating languages : English, German, French, Spanish,
Russian, Arabic (other available on request)
Quantity and units of measurement
Volumetric flow rate : m3/h, m3/min, m3/s, l/h, l/min, l/s,
USgal/h (US gallons per hour),
USgal/min, USgal/s, bbl/d (barrels
per day), bbl/h, bbl/min, bbl/s
Flow velocity : m/s, ft/s, inch/s
Mass flow rate : g/s, t/h, kg/h, kg/min
Volume : m
3
, l, gal (US gallons), bbl
Mass : g, kg, t
Heat flow : W, kW, MW (only with heat quantity
measurement option)
Heat quantity : J, kJ, MJ (only with heat quantity
measurement option)
Sig dB (signal), noise dB, SNR,
C m/s (sound speed), CU (housing temperature)
Tin, Tout (inlet and outlet temperature)
Communication
Serial interface : RS 232, RS 485, Modbus RTU, HART (optional)
Data : Measured data, parameter set and configuration,
Software
Functionality : Downloading of measured values/parameter sets, graphical presentation, list
format, export to third party software, on-line transfer of measured data
Operating systems : Windows 2000, NT, XP, Vista, 7; Linux; Mac (optional)