KATflow 100
5 Commissioning
5.4.4 Analogue current output 0/4 ... 20 mA
The analogue current outputs operate in a 4 ... 20 mA or 0 ... 20 mA span.
Current outputs may be assigned to process values in the “mode” section of the
output menu. The outputs can be programmed and scaled within the menu
structure.
Wiring
Electrical
characteristic
s
0/4...20 mA active and 4...20 mA passive options.
Galvanically isolated from main electronics and from other I/O's.
Passive: U=9...30 V, RLoad=50 ohm typical.
Resolution: 16 bit.
Accuracy: 0.1 % of MV.
Active: RLoad<500 ohm, U=30 V.
Resolution: 16 bit.
Accuracy: 0.1 % of MV.
5.4.5 Analogue voltage output 0 – 10 v
Voltage outputs may be assigned to process values in the “mode” section of the
output menu. The outputs can be programmed and scaled within the menu
structure.
Wiring
Electrical
characteristic
s
Galvanically isolated from main electronics and from other I/O's.
Range 0...10 V.
RLoad=1000 ohm.
Resolution: 16 bit.
Accuracy: 0.1% of MV.
5.4.6 Analogue frequency output (passive)
Frequency outputs may be assigned to process values in the “mode” section of the
output menu. The outputs can be programmed and scaled within the menu
structure.
Wiring
Electrical
characteristic
s
Galvanically isolated from main electronics and from other I/O's.
Open-collector: 2...10000 Hz.
U=24 V, Imax=4 mA.
35