KATflow 100
5 Commissioning
Liner c-speed
Only if lining material selected
600 ... 6553.0 m/s
Liner thickness
Only if lining material selected
1.0 ... 99.0 mm
Passes
Select from list ↑↓
Auto
1...16
Totalizer
Off, On,
Reset + (positive total), Reset – (negative total)
Reset Both
[Programmer] Read / Write
Flowmeter
Acquires or sends parameters from / to a
connected flowmeter
Sensor
positioning
Sensor positioning screen
Start / Stop
Begins / ends measurement
Diagnostics
[where specified]
Scope
Shows graph of received signal against time
[where specified]
Stored Setups
Load, save and delete stored parameters
[Screen]
Start
Measurement
Sensor type
Indication of sensor type and serial number if
automatically detected, otherwise
select from list ↑↓
K1
K4
M
Q
Special
Sensor
frequency
SP1, only for special, unrecognised sensors
Wedge angle
SP2, only for special, unrecognised sensors
Wedge c-speed
1
SP3, only for special, unrecognised sensors
Wedge c-speed
2
SP4, only for special, unrecognised sensors
Crystal offset
SP5, only for special, unrecognised sensors
Spacing offset
SP6, only for special, unrecognised sensors
Zero flow offset
SP7, only for special, unrecognised sensors
Upstream
offset
SP8, only for special, unrecognised sensors
Sensor
placement
Installation
Pipe
Material
Select from pipe material list ↑↓
Outside
diameter
6 ... 6500 mm
Wall thickness
0.5 ... 75 mm
Pipe c-speed
600 ... 6553.5 m/s
Pipe
circumference
18.8 ... 20420.4 mm
Roughness
0.0 ... 10 mm
Medium
Fluid
Select from fluid list ↑↓
Kinematic
(viscosity)
0.001 ... 30000 mm
2
/s
29