P r o g r a m m i n g I o P a s s ™ - F e a t u r e s
- Door Ajar Alarm Function
16
(without card or password or both). When this occurs, a
“door forced open” type of event is generated.
NOTE:
For more information refer to “5.11 Configuring the
4.8
Door Ajar Alarm Function
Already enabled in the unit, this function activates the
“Alarm Relay” when the door is opened longer than the
pre-set time following an access granted operation.
The user can decide if the alarm relay needs to be activated
when this situation occurs.
NOTE:
Please refer to “5.12 Configuring the Door Ajar
Function”, page 24 for more information.
4.9
PIN Error Alarm Function
This function, if enabled, will automatically activate the
“Alarm Relay” when a cardholder keys in his PIN
incorrectly five (5) times consecutively within four (4)
minutes.
Furthermore, the card can automatically be deleted (from
the unit’s memory) when this situation occurs.
NOTE:
Please refer to “5.13 PIN Error Function
Configuration”, page 25 for more information.
4.10
Beeper Key Tone Function
This function, already enabled in the unit, provides an
audible “beep” tone when the keys of the keypad are used.
NOTE:
Please refer to “5.14 Beeper Key Tone
Configuration”, page 26 for more information.
4.11
Loop Type Selection
The IoPass unit allows the installer to modify the loop type
of the exit button and door contact.
These normally open contacts can be modified to normally
closed to suit installer’s requirements.
NOTE:
For more information refer to “5.15 Loop Type
4.12
Strike Relay Activation Timer
By default, the locking device relay is pre-set to 10
seconds, meaning that the door will remain unlocked for
that period of time.
The timer can be modified from 1-255 seconds.
NOTE:
For more information refer to “5.17 Setting the
4.13
Reset to Factory Default
A reset function is available in the unit. It is used to clear
all configured options and cards from the unit memory
which will bring back the IoPass unit to factory defaults.
To clear the memory, the master password is required.
NOTE:
For more information refer to “Resetting the IoPass
Unit to Factory Defaults” (page 27).
4.14
Selecting the System Language
IoPass offers users the ability to select the System operating lan-
guage. You can operate the system in English, French, Spanish,
German and Dutch.
NOTE:
For more information on setting the system
language, refer to “Selecting the System Language” (page
17).
Содержание IoPass SA-500
Страница 4: ......
Страница 6: ...vi ...
Страница 12: ...Installing and Wiring IoPass Connecting the Power 12 General Wiring Diagram ...
Страница 14: ...Programming IoPass Introduction IoPass Factory Defaults 14 ...
Страница 33: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 33 ...
Страница 34: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 34 ...
Страница 35: ......