P r o g r a m m i n g I o P a s s ™ - S t e p b y S t e p
- S e t t i n g t h e S t r i k e R e l a y T i m e r
27
3.DURESS 4.AJAR
3.
Press [2-Alarm]. The LCD displays:
CURRENT: 240 SEC.
NEW:
4.
Using the keypad, enter the number of seconds
during which the alarm will sound. Enter digits in
“seconds”. Press [#] to save and exit.
5.17
Setting the Strike Relay Timer
By default, the locking device relay is pre-set to 10
seconds, meaning that the door will remain unlocked for
that period of time following an “access granted” event.
The timer can be modified from 1-255 seconds.
To set the strike relay timer:
1.
Enter the master password (default is [111111]) fol-
lowed by the [#] key. The LCD displays the follow-
ing:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [3-Timer]. The LCD displays:
1.STRIKE 2.ALARM
3.DURESS 4.AJAR
3.
Press [1-Strike]. The LCD displays:
CURRENT: 10 SEC.
NEW:
4.
Using the keypad, enter the number of seconds
during which the locking device will be unlocked.
Enter digits in “seconds”. Press [#] to save and exit.
5.18
Resetting the IoPass Unit to Factory Defaults
The reset to factory default option is used to clear all
configured options and cards from the IoPass memory and
bring back the unit to factory defaults.
To clear the memory, the master password is required. A
double confirmation is used to confirm memory deletion.
1.
Enter the master password (default is [111111]) fol-
lowed by the [#] key. The LCD displays the follow-
ing:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [4-System]. The LCD displays:
1.ALARM
2.CHECK
3.MODE
4.OTHER
3.
Press [4-Other]. The LCD displays:
1.TONE
2.DURESS
3.MORE
4. LANGUAGE
4.
Press [3-More]. The LCD displays:
1.GUARD
2.AUX.CR
3.A_DEL
4.RESET
5.
Press [4-Reset]. The LCD displays:
PRESS 1
TO RESET THE UNIT
6.
Press [1]. The LCD displays:
PASSWORD:
7.
Enter the master password (default is [111111])
followed by the # key. The LCD displays:
PRESS 1
TO RESET THE UNIT
8.
Press [1] to confirm your action. If you are not sure,
press the [*] to cancel.
All cards will be deleted from the memory and set-
tings will return to factory defaults. While process-
ing, the LCD displays:
EEPROM ERASING
9.
When completed, the unit will return to the welcome
screen.
NOTE:
If power is removed from unit during the process
before the above message is displayed, the following
message will be displayed when unit is powered again:
CNA CHECKSUM EM
1=CLEAR
2=IGNORE
• Press [1-Clear] will continue the reset process.
• Press [2-Ignore] will stop the process to where it was
interrupted. Consequently, most of the unit
configuration will be reset to default settings,
whereas some cards may remain in the unit.
Содержание IoPass SA-500
Страница 4: ......
Страница 6: ...vi ...
Страница 12: ...Installing and Wiring IoPass Connecting the Power 12 General Wiring Diagram ...
Страница 14: ...Programming IoPass Introduction IoPass Factory Defaults 14 ...
Страница 33: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 33 ...
Страница 34: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 34 ...
Страница 35: ......