I n s t a l l i n g a n d W i r i n g I o P a s s ™
- U n p a c k i n g t h e I o P a s s U n i t
9
S e c t i o n 2 • I n s t a l l i n g a n d Wi r i n g I o P a s s ™
2.1
Unpacking the IoPass Unit
Check that the following parts are in your IoPass package:
• One (1) IoPass unit (SA-500 or SA-600);
• One (1) relay module (SA-RM56 including connectors);
• One (1) hardware kit;
• Ten (10) proximity keytags (P40KEY);
• One (1) IoProx P100 proximity reader (with SA-600
model only).
NOTE:
The SA-RM56 relay module comes with all the
necessary connectors to facilitate installation.
2.2
Required Equipment
• Power supply—12VDC, 1A (required);
• Cables (required):
•
Between IoPass and reader
2 twisted pairs, solid conductor #22AWG
UNSHIELDED
•
Between IoPass and relay module
2 twisted pairs, solid conductor, #22AWG
UNSHIELDED
•
Between relay module and power supply
1 pair, solid conductor #22AWG UNSHIELDED
NOTE:
Maximum wiring distance between equipment—
150m (500’).
• Door contact (recommended);
• Locking device (required);
• Door alarm or annunciator (recommended);
• T.Rex Request-to-Exit detector (recommended).
2.3
Selecting a Mounting Location
Select a mounting location for the unit using the following
guidelines:
• Close to the door being supervised;
• Away from areas with a large amount of background
noise;
• It is recommended that you mount the unit so that the
LCD is visible to users when requesting access. The top
of the unit should not be higher than 45 to 50 inches
from the floor.
2.4
Typical Mounting Diagram
2.5
Mounting the IoPass Unit
1.
Remove the front panel by squeezing the sides of the
unit and sliding forward;
2.
Use the provided paper-sticker template to mark the
position of the holes on the wall;
3.
Mount the base unit to the wall using four (4) screws
(provided) to secure the unit to the wall;
4.
Replace the cover by gently sliding it back on the
unit;
5.
The unit offers a tamper alarm protection in case
someone tries to remove the cover. For more
information, please refer to “Configuring the Tamper
Alarm Function” (page 23).
Содержание IoPass SA-500
Страница 4: ......
Страница 6: ...vi ...
Страница 12: ...Installing and Wiring IoPass Connecting the Power 12 General Wiring Diagram ...
Страница 14: ...Programming IoPass Introduction IoPass Factory Defaults 14 ...
Страница 33: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 33 ...
Страница 34: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 34 ...
Страница 35: ......