P r o g r a m m i n g I o P a s s ™ - S t e p b y S t e p
- C o n f i g u r i n g t h e D u r e s s F u n c t i o n ( R e l a y - 1 )
23
5.9
Configuring the Duress Function (Relay-1)
The duress function is used to provide added security to
personnel. In situations of duress, a cardholder enters his
code (PIN) with a trailing digit [9] and the duress relay will
be activated (timer can be modified) to drive the require
device.
NOTE:
This function can only be used when the system is
programmed to use access mode 1 or 2. The number [9]
can be inserted at the end of the PIN or the main password.
NOTE:
The relay will be activated and access will be
granted normally. The relay activation timer can be modified
(normally set to 10 seconds).
Recommended Configuration Procedure
• Jumper set up (relay module). See “Jumper Settings:”
• Enable duress function;
• Modify duress active timer setting (if required).
5.9.1 - Enabling the Duress Function
1.
To enter the programming mode, enter the master
password (default is [111111]) followed by the [#]
key. The LCD displays the following:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [4-System]. The LCD displays:
1.ALARM
2.CHECK
3.MODE
4.OTHER
3.
Press [4-Other]. The LCD displays:
1.TONE
2.DURESS
3.MORE
4. LANGUAGE
4.
Press [2-Duress]. The LCD displays:
CURRENT: ENABLE
PRESS ’1’ --> CHANGE
5.
Press [1] until desired mode is displayed. Pressing
this key will toggle between selections. When
required mode is displayed (in this case “Enable”),
press [#] to save and exit.
5.9.2 - Setting the Duress Relay Timer
By default, the relay-1 timer for the duress function is set
to be activated for 10 seconds.
If required, you can modify this setting and program a
value between 1-255 seconds.
1.
To enter the programming mode, enter the master
password (default is [111111]) followed by the [#]
key. The LCD displays the following:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [3-Timer]. The LCD displays:
1.STRIKE 2.ALARM
3.DURESS 4.AJAR
3.
Press [3-Duress]. The LCD displays:
CURRENT: 10 SEC.
NEW:
4.
Using the keypad, enter the number of seconds
during which the duress relay will remain activated.
Enter digits in “seconds”. Press [#] to save and exit.
5.9.3 - Using the Duress Function
Once the function is enabled in the system, follow this
procedure to use the duress function:
1.
Present your card at the reader (skip this step if you
are using mode 2);
2.
Key in your PIN (if mode 1) immediately followed
by the digit [9].
Example:
55559
followed by [#]
3.
The door will open normally (access granted) and the
relay will activate for the pre-set period of time.
5.10
Configuring the Tamper Alarm Function
This tamper alarm will activate the alarm relay when the
front cover of the IoPass unit is removed.
Recommended Configuration Procedure
• Enable tamper function;
• Modify alarm relay timer activation (if required). See
“5.16 Alarm Relay Timer Configuration”, page 26 for
more information.
5.10.1 - Enabling the Tamper Alarm Function
1.
To enter the programming mode, enter the master
password (default is [111111]) followed by the [#]
key. The LCD displays the following:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [4-System]. The LCD displays:
1.ALARM
2.CHECK
3.MODE
4.OTHER
3.
Press [1-Alarm]. The LCD displays:
1.TAMPER 2.FORCE
3.D_AJAR 4.P_ERR
4.
Press [1-Tamper]. The LCD displays:
CURRENT: DISABLE
PRESS ’1’ --> CHANGE
5.
Press [1] until desired mode is displayed. Pressing
this key will toggle between selections. When
required mode is displayed (in this case “Enable”),
press [#] to save and exit.
Содержание IoPass SA-500
Страница 4: ......
Страница 6: ...vi ...
Страница 12: ...Installing and Wiring IoPass Connecting the Power 12 General Wiring Diagram ...
Страница 14: ...Programming IoPass Introduction IoPass Factory Defaults 14 ...
Страница 33: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 33 ...
Страница 34: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 34 ...
Страница 35: ......