P r o g r a m m i n g I o P a s s ™ - S t e p b y S t e p
- Auxiliary Function Configuration (Relay-1)
22
To disarm the system:
1.
Enter the
Guard code
[123] followed by the [#] key.
2.
The LCD prompts for a card:
CARD PLEASE
3.
Present a card to the reader then enter the
cardholder’s PIN (any card associated with a PIN and
that has been programmed in the unit will do).
4.
The relay will be triggered and the system will
disarm. Depending on how the system is set up, the
strike may activate or deactivate.
The LCD will return to the normal greeting display and the
red LED will not flash. When the door unlocks, access is
granted instantly. When the door remains locked, you must
present your card to the reader to be granted access.
5.7.3 - Viewing the Audit Trail
1.
Enter the master password [111111, default]. The
LCD displays the following:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Select [4. System]. The LCD displays:
1. ALARM 2. CHECK
3. MODE
4. OTHER
3.
Select [2. Check]. The LCD displays:
1. CHECK CARD NO.
2. RECORD CHECK.
4.
Select [2. Record check]. Then scroll the audit trail
by using [1] or [2]. The events will appear as
follows:
[1 ACC 41:4118]
for access granted
[1.Up 2 Down]
[2 ARM 41:4118]
for arming
[1.Up 2.Down]
[3 DIS 41:4118]
for disarming
[1.Up 2. Down]
5.8
Auxiliary Function Configuration (Relay-1)
The auxiliary function is used to trigger a device without
unlocking the door. The auxiliary relay can be used to
activate such devices as lighting control, HVAC control, or
to unlock an auxiliary door.
The system will
either
accept an auxiliary card or the
auxiliary code to activate the relay.
NOTE:
The relay will be activated for a period of 3 seconds,
then will deactivate automatically (this delay cannot be
modified).
Recommended Configuration Procedure
• Jumper set up (relay module). See “Jumper Settings:”
• Enable auxiliary function;
• Modify auxiliary password. See “ To Modify the
Auxiliary Password:”, page 18;
• Enroll auxiliary cards (if required). See “5.4.3 - Adding
& Deleting Auxiliary Cards”, page 20.
5.8.1 - Enabling the Auxiliary Function
1.
To enter the programming mode, enter the master
password (default is [111111]) followed by the [#]
key. The LCD displays the following:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [4-System]. The LCD displays:
1.ALARM
2.CHECK
3.MODE
4.OTHER
3.
Press [4-Other]. The LCD displays:
1.TONE
2.DURESS
3.MORE
4.LANGUAGE
4.
Press [3-More]. The LCD displays:
1.GUARD
2.AUX.CR
3.A_DEL
4.RESET
5.
Press [2-Aux. Cr]. The LCD displays:
CURRENT: ENABLE
PRESS ’1’ --> CHANGE
6.
Press [1] until desired mode is displayed. Pressing
this key will toggle between selections. When
required mode is displayed (in this case “Enable”),
press [#] to save and exit.
Содержание IoPass SA-500
Страница 4: ......
Страница 6: ...vi ...
Страница 12: ...Installing and Wiring IoPass Connecting the Power 12 General Wiring Diagram ...
Страница 14: ...Programming IoPass Introduction IoPass Factory Defaults 14 ...
Страница 33: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 33 ...
Страница 34: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 34 ...
Страница 35: ......