P r o g r a m m i n g I o P a s s ™ - I n t r o d u c t i o n
- I o P a s s P r o g r a m m i n g M o d e
13
S e c t i o n 3 • P r o g r a m m i n g I o P a s s ™ - I n t r o d u c t i o n
3.1
IoPass Programming Mode
To enter the programming mode, you have to enter the 6-
digit Master Password followed by the [#] key. The default
Master Password is [111111].
The LCD will display the following information:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
From these basic functions, more options are available.
When programming the unit, you need to know that:
• The
[*]
key is used to either go back to the previous
menu, or delete what was entered.
• The
[#]
key is used to accept, save the data that was
modified or programmed in the system and quit.
3.2
IoPass Factory Defaults
The factory defaults consists of a series of options that are
automatically set up in the unit as the “basic” system
configuration and can be modified.
Description
Factory
Default
To
Modify
Access mode
Card only (mode 0)
Master password
111111 (always
enabled)
Main password
1234 (always
enabled)
Duress function
Disabled
Auxiliary function
Disabled
Auxiliary password
1234567 (default)
when enabled
Guard function
Disabled
Guard password
123 (default)
when enabled
Tamper alarm func-
tion
Disabled
Forced entry alarm
function
Enabled
Door ajar
Enabled
Alarm relay acti-
vated on door ajar
Disabled
Incorrect PIN keyed
in incorrectly five
times activates
alarm relay (P-ERR)
Disabled
Card auto-deletion
on PIN error (5
times)
Disabled
Beeper key tones
Enabled
Alarm relay activa-
tion timer when
door left open more
then the preset time
(door ajar)
30 seconds (has to
remain open more
than 30 seconds to
trigger alarm
relay—if the func-
tion is enabled)
Duress relay active
time (Relay-1)
10 seconds (when
enabled)
Auxiliary relay
active (Relay-1)
time
3 seconds
Cannot be
modified
Guard relay active
time (Relay-1)
Remains activated
until deactivated
manually
Cannot be
modified
Alarm relay active
time
240 seconds
(4 min.)
Strike relay active
time
10 seconds
Exit button input
type
Normally Open
(NO)
Door contact type
Normally Open
(NO)
Description
Factory
Default
To
Modify
Содержание IoPass SA-500
Страница 4: ......
Страница 6: ...vi ...
Страница 12: ...Installing and Wiring IoPass Connecting the Power 12 General Wiring Diagram ...
Страница 14: ...Programming IoPass Introduction IoPass Factory Defaults 14 ...
Страница 33: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 33 ...
Страница 34: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 34 ...
Страница 35: ......