P r o g r a m m i n g I o P a s s ™ - S t e p b y S t e p
- V e r i f y i n g a C a r d N u m b e r
21
3.
Press [1-Access Card] to view access cards OR press
[2-Aux. Card] to view auxiliary cards . The LCD
displays:
1. PROGRAM CARDS
2. VIEW CARDS
4.
Press [2-View Cards]. The LCD displays:
XXXX
ID_XX:XXXXX
1.NEXT
2.PREV.
(XXXX indicates the cards programming
sequence in the unit’s memory)
5.6
Verifying a Card Number
This feature is particularly useful when the card number is
no longer visible on the card.
1.
Enter the master password (default is [111111]) fol-
lowed by the [#] key. The LCD displays the follow-
ing:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [4-System]. The LCD displays:
1.ALARM
2.CHECK
3.MODE
4.OTHER
3.
Press [2-Check]. The LCD displays:
1.CHECK CARD NO.
2.RECORD CHECK
4.
Press [1-Check Card No.]. The LCD displays:
CARD PLEASE
CARD NO.
5.
Present the card to the reader. The LCD displays the
associated card number:
CARD PLEASE
CARD NO.: XX:XXXXX
6.
To exit and return to the main menu, press the [#] key.
5.7
Guard Function Configuration (Relay-1)
NOTE:
Are your jumpers configured correctly to use this
function? For more information, please refer to “Jumper
Settings:” (page 11).
This function is used to arm/disarm the connected security
system. Either by using a password and card, or simply a
password to arm the system.
NOTE:
The relay will be triggered and will remain activated
until the system is disarmed.
Recommended Configuration Procedures
• Jumper setup (relay module). Refer to “Jumper
• Enable guard function. Refer to “Enabling the Guard
• Modify guard code. Refer to “ To Modify the Guard
5.7.1 - Enabling the Guard Function
To enable the guard function:
1.
Enter the master password (default is [111111]) fol-
lowed by the [#] key. The unit displays the following:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [4-System]. The LCD displays:
1.ALARM
2.CHECK
3.MODE
4.OTHER
3.
Press [4-Other]. The LCD displays:
1.TONE
2.DURESS
3.MORE
4. LANGUAGE
4.
Press [3-More]. The LCD displays:
1.GUARD
2.AUX.CR
3.A_DEL
4.RESET
5.
Press [1-Guard]. The LCD displays:
1.GUARD FUNCTION
2.STRIKE ACTIVE
6.
Select [1-Guard Function]. The LCD displays:
CURRENT: ENABLE
PRESS ’1’ --] CHANGE
7.
Press [1] until the desired mode is displayed, then
press [#] to save and exit.
5.7.2 - Arming / Disarming Quick Reference
Only cards that are associated with a PIN can be used for
arming/disarming the unit.
NOTE:
You have 20 seconds to arm/disarm the system.
Passed this delay, the LCD displays a “Time-Out” message
and returns to the normal greeting screen.
To arm the IoPass unit:
1.
Enter the
Guard code
(default is [123]) then press
[#]
. The LCD will prompt:
CARD PLEASE
2.
Present a card to the reader.
3.
Enter the cardholder’s PIN (any card associated with
a PIN and that has been programmed in the unit will
do). Once you have presented the card and entered
the PIN, the relay will be triggered (and will remain
activated until disarmed). The LCD displays:
ARMED
4.
The LED will blink RED to indicate the armed
status.
To disarm the IoPass unit:
The system has to be disarmed in order to grant access.
When a card is presented to the reader when the system is
still armed, an “invalid card message” is displayed. Users
have to enter the system Guard code, then present their
card and enter their PIN.
Содержание IoPass SA-500
Страница 4: ......
Страница 6: ...vi ...
Страница 12: ...Installing and Wiring IoPass Connecting the Power 12 General Wiring Diagram ...
Страница 14: ...Programming IoPass Introduction IoPass Factory Defaults 14 ...
Страница 33: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 33 ...
Страница 34: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 34 ...
Страница 35: ......