P r o g r a m m i n g   I o P a s s ™ - S t e p   b y   S t e p

 - Viewing Cards

20

To Add/Delete a group of cards:

1.

Enter the master password (default is [111111]) fol-
lowed by the [#] key. The LCD displays the follow-
ing:

1. ENROLL

2. PASSWD

3. TIMER

4. SYSTEM

2.

Press [1-Enroll]. The LCD displays:

1-ACCESS CARD

2-AUX. CARD

3.

Press [1-Access Card]. The LCD displays:

1. PROGRAM CARDS

2. VIEW CARDS

4.

Press [1-Program Cards]. The LCD displays:

1. S_ADD

2. S_DEL

3. B_ADD

4. B_DEL

5.

Press [3-B_Add] to add cards or [4-B_Del] to delete a 
batch of cards. The LCD displays:

TOTAL CARDS: XX 

(xx=#cards in unit)

CARD NO.__:______

6.

There are two ways to enter the card number in the 
system:

• You can simply present the card to the reader and the 

number will automatically be entered.

• enter the card number manually followed by the [#]. 

To enter special characters (hexadecimal) refer to the 
section “Special Characters (Hexadecimal)” (page 
19).

7.

Once you have entered the first card number, the 
LCD will display the following screen:

CARD NO. XX:XXXXX

TOTAL: 

8.

Enter the total number of sequential cards that you 
wish to add/delete followed by the [#] key to accept. 
The LCD will display:

Processing...xx 

For example

 if you wanted to add 250 cards that are 

sequentially numbered you would enter the first card 
(lowest) number and then select 250 for the total. If 
for example you enter [01:00001] as the first card 
number, the system would automatically program 
cards [01:00001] to [01:00250] into the system.

NOTE: 

Cards that were enrolled in the unit using the “batch 

mode” will function without having to enter the PIN, even if 
the mode is selected. You will have to enter the PINs using 
the Single Add feature.  When you delete a card, the PIN 
associated with the card is also deleted. 

5.4.3 - Adding & Deleting Auxiliary Cards

Auxiliary cards are used to activate an external device 
without unlocking the door. For more information, refer to 
“5.8 Auxiliary Function Configuration (Relay-1)”, page 
22.

To Add/delete Auxiliary Cards:

1.

Enter the master password (default is [111111]) fol-
lowed by the [#] key. The LCD displays the follow-
ing:

1. ENROLL

2. PASSWD

3. TIMER

4. SYSTEM

2.

Press [1-Enroll]. The LCD displays:

1-ACCESS CARD

2-AUX.CARD

3.

Press [2-Aux.Card]. The LCD displays:

1. PROGRAM CARDS

2. VIEW CARDS

4.

Press [1-Program Cards]. The LCD displays:

1. S_ADD

2. S_DEL

5.

Press [1-S_Add] to add a card or [2-S_Del] to delete 
a card. The LCD displays:

TOTAL CARDS: XX

CARD NO.__:______

6.

Enter the card number in the system by simply 
presenting the card to the reader, or by entering the 
card number manually followed by the [#]; to enter 
special characters refer to “Special Characters 
(Hexadecimal)” (page 19). 

7.

Once you have entered the card number, the LCD 
will display:

ACCEPTED

8.

Once the card has been accepted, the system will 
return to the add/delete card screen. To add or delete 
another card simply repeat steps 5 and up. To exit the 
programming mode press [#], [#].

5.5

Viewing Cards

You may view the cards that are programmed in the unit’s 
memory. These are sorted based or their programming 
order within the unit. For example, if cards numbered 
01:00000 to 01:00005 are programmed and you delete the 
card number 01:00004, when you add a new card (for 
example 01:00009), it is placed where the last card was 
deleted: 01:00000, 01:00001, 01:00002, 01:00003, 

01:00009

, 01:00005.

1.

Enter the master password (default is [111111]) fol-
lowed by the [#] key. The LCD displays the follow-
ing:

1. ENROLL

2. PASSWD

3. TIMER

4. SYSTEM

2.

Press [1-Enroll]. The LCD displays:

1-ACCESS CARD

2-AUX. CARD

Содержание IoPass SA-500

Страница 1: ...on on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read IoPass Stand Alone Door Controller Installation Manual DN1445 0303 V 2 22 ...

Страница 2: ... of insuffi cient coverage disconnecting a device immediately following a per son through the controlled gate or door or interfering with the proper operation of the system Power Failure Control units intrusion detectors smoke detectors and many other security devices require an adequate power supply for proper opera tion If a device operates from batteries it is possible for the batteries to fail...

Страница 3: ...Systems s liability for failure to repair the product under this warranty after a reasonable number of attempts will be limited to a replacement of the product as the exclusive remedy for breach of war ranty Under no circumstances shall Kantech Systems be liable for any special incidental or consequential damages based upon breach of warranty breach of contract negligence strict liability or any o...

Страница 4: ......

Страница 5: ...2 Modifying the Main Password 18 5 3 3 Modifying the Auxiliary Password 18 5 3 4 Modifying the Guard Password 18 5 4 Adding Deleting Cards 19 5 4 1 Single Add Single Deletion 19 5 4 2 Batch Add Batch Deletion 19 5 4 3 Adding Deleting Auxiliary Cards 20 5 5 Viewing Cards 20 5 6 Verifying a Card Number 21 5 7 Guard Function Configuration Relay 1 21 5 7 1 Enabling the Guard Function 21 5 7 2 Arming D...

Страница 6: ...vi ...

Страница 7: ... the IoPass firmware as of version 2 22 The new features include 1 Reset function you can clear the IoPass memory and reset it to factory default values 2 View function you can view the next and previous card access and auxiliary card programmed in the system 3 Custom language selection the IoPass unit can be operated in five languages English French Spanish German and Dutch 4 More transaction in ...

Страница 8: ...ndicator Bicolor green red Operating temperatures 0 C to 50 C 32 F to 122 F Operating humidity 5 to 95 relative humidity non condensing Door contact input NO or NC selectable Request to Exit input NO or NC selectable Relay output Strike Alarm and Relay 1 relay Form C NO and NC 3A 24VDC Strike Alarm and Relay 1 timer 1 to 255 sec Door ajar timer 1 to 255 sec Audit trail On unit last 380 transaction...

Страница 9: ...tact recommended Locking device required Door alarm or annunciator recommended T Rex Request to Exit detector recommended 2 3 Selecting a Mounting Location Select a mounting location for the unit using the following guidelines Close to the door being supervised Away from areas with a large amount of background noise It is recommended that you mount the unit so that the LCD is visible to users when...

Страница 10: ...ng the Door Locking Device To install the door locking device refer to the manufacturer s instructions To connect it refer to the diagram below Wiring Diagram 2 8 Connecting the T Rex Exit Detector or Exit Button To install the T Rex Exit Detector push button refer to the manufacturer s instructions To connect it refer to the diagram below Wiring Diagram 2 9 Connecting the Door Contact To install ...

Страница 11: ...For more information on the relay function please refer to Relay 1 Functions page 15 Jumper Settings 2 12Connecting the Power Once all other wiring is complete power up the unit Wiring Diagram NOTE Once all connections are finished you may start to program the unit Before you do so we recommend you read the section called Programming IoPass Introduction page 13 Relay 1 Function Function 1 2 3 DURE...

Страница 12: ...Installing and Wiring IoPass Connecting the Power 12 General Wiring Diagram ...

Страница 13: ...bled See p 23 Auxiliary function Disabled See p 22 Auxiliary password 1234567 default when enabled See p 18 Guard function Disabled See p 21 Guard password 123 default when enabled See p 18 Tamper alarm func tion Disabled See p 23 Forced entry alarm function Enabled See p 24 Door ajar Enabled See p 24 Alarm relay acti vated on door ajar Disabled See p 24 Incorrect PIN keyed in incorrectly five tim...

Страница 14: ...Programming IoPass Introduction IoPass Factory Defaults 14 ...

Страница 15: ...0 5 5 Viewing Cards page 20 5 6 Verifying a Card Number page 21 4 4 Relay 1 Functions The Relay 1 located on the relay module function depends on your requirements There are three 3 possibilities but ONLY ONE can be configured Depending on your choice the jumpers of the relay module need to be set up accordingly Guard Function This function is used to arm dis arm the connected security system Eith...

Страница 16: ...e keypad are used NOTE Please refer to 5 14 Beeper Key Tone Configuration page 26 for more information 4 11 Loop Type Selection The IoPass unit allows the installer to modify the loop type of the exit button and door contact These normally open contacts can be modified to normally closed to suit installer s requirements NOTE For more information refer to 5 15 Loop Type Configuration page 26 4 12St...

Страница 17: ...ure the keypad can be accessed by cardholders if you are using this mode Mode 2 Card only OR main password only This mode will require that the user presents his card to the reader to be granted access OR enters his main password using the keypad to be granted access To Select an Access Mode 1 Enter the master password default is 111111 NOTE It is strongly recommended to modify the default passwor...

Страница 18: ...o activate the auxiliary relay To Modify the Auxiliary Password 1 Enter the master password default is 111111 then The LCD displays the following 1 ENROLL 2 PASSWD 3 TIMER 4 SYSTEM 2 Press 2 Passwd The LCD displays the following 1 MASTER 2 MAIN 3 AUX CR 4 GUARD 3 Press 3 Aux Cr The LCD displays the default password and invites you to enter a new one Current 1234567 New 4 Enter the new auxiliary pa...

Страница 19: ...it The LCD displays TOTAL CARDS XX xx of cards in unit CARD NO __ ______ 6 There are two ways to enter the card number in the system You can simply present the card to the reader and the number will automatically be entered You can type in the number XX XXXXX printed on the card followed by the sign using the keypad If you need to enter special characters hexadecimal see Special Characters Hexadec...

Страница 20: ...re When you delete a card the PIN associated with the card is also deleted 5 4 3 Adding Deleting Auxiliary Cards Auxiliary cards are used to activate an external device without unlocking the door For more information refer to 5 8 Auxiliary Function Configuration Relay 1 page 22 To Add delete Auxiliary Cards 1 Enter the master password default is 111111 fol lowed by the key The LCD displays the fol...

Страница 21: ...unction page 21 Modify guard code Refer to To Modify the Guard Password page 18 5 7 1 Enabling the Guard Function To enable the guard function 1 Enter the master password default is 111111 fol lowed by the key The unit displays the following 1 ENROLL 2 PASSWD 3 TIMER 4 SYSTEM 2 Press 4 System The LCD displays 1 ALARM 2 CHECK 3 MODE 4 OTHER 3 Press 4 Other The LCD displays 1 TONE 2 DURESS 3 MORE 4 ...

Страница 22: ...Up 2 Down 5 8 Auxiliary Function Configuration Relay 1 The auxiliary function is used to trigger a device without unlocking the door The auxiliary relay can be used to activate such devices as lighting control HVAC control or to unlock an auxiliary door The system will either accept an auxiliary card or the auxiliary code to activate the relay NOTE The relay will be activated for a period of 3 sec...

Страница 23: ...g and program a value between 1 255 seconds 1 To enter the programming mode enter the master password default is 111111 followed by the key The LCD displays the following 1 ENROLL 2 PASSWD 3 TIMER 4 SYSTEM 2 Press 3 Timer The LCD displays 1 STRIKE 2 ALARM 3 DURESS 4 AJAR 3 Press 3 Duress The LCD displays CURRENT 10 SEC NEW 4 Using the keypad enter the number of seconds during which the duress rela...

Страница 24: ...ode is displayed Pressing this key will toggle between selections When required mode is displayed press to save and exit 5 11 2 Using the Force Entry Function Follow this procedure to STOP the force entry alarm if it has been activated 1 When the force entry has been activated the alarm relay will be triggered usually an annunciator and the LCD will display READY FOR CARD FORCE ENTRY 2 This Force ...

Страница 25: ... Ajar Function Depending if the door ajar function is configured to trigger the alarm relay follow this procedure to STOP the warning device 1 When the door is left opened the alarm relay will be triggered OR the unit s piezo will sound The LCD will display READY FOR CARD DOOR OPEN 2 The Door Open message is displayed and blinking and will remain on the LCD until the door is closed properly 5 13PI...

Страница 26: ...n and door contact These normally open contacts can be modified to normally closed to suit installer s requirements To configure the loop type 1 Enter the master password default is 111111 fol lowed by the key The LCD displays the follow ing 1 ENROLL 2 PASSWD 3 TIMER 4 SYSTEM 2 Press 4 System The LCD displays 1 ALARM 2 CHECK 3 MODE 4 OTHER 3 Press 3 Mode The LCD displays 1 ACCESS MODE 2 DOOR_INPUT...

Страница 27: ...o clear the memory the master password is required A double confirmation is used to confirm memory deletion 1 Enter the master password default is 111111 fol lowed by the key The LCD displays the follow ing 1 ENROLL 2 PASSWD 3 TIMER 4 SYSTEM 2 Press 4 System The LCD displays 1 ALARM 2 CHECK 3 MODE 4 OTHER 3 Press 4 Other The LCD displays 1 TONE 2 DURESS 3 MORE 4 LANGUAGE 4 Press 3 More The LCD dis...

Страница 28: ...CARDS 1 S_ADD VIEW CARDS 2 S_DEL 2 PASSWD 1 MASTER 2 MAIN 3 AUX CR 4 GUARD 3 TIMER 1 STRIKE 2 ALARM 3 DURESS 4 AJAR 4 SYSTEM 1 ALARM 1 TAMPER 2 FORCE 3 D_AJAR 1 DOOR TIMER 2 ALARM RELAY 4 P_ERR 2 CHECK 1 CHECK CARD NO 2 RECORD CHECK 3 MODE 1 ACCESS MODE 2 DOOR_INPUT 1 EXIT BUTTON 2 DOOR 4 OTHER 1 TONE 2 DURESS 3 MORE 1 GUARD 1 GUARD FUNCTION 4 LANGUAGE 2 STRIKE ACTIVE 1 ENABLE 2 DISABLE 2 AUX CARD...

Страница 29: ...ramming mode To enter programming mode enter your 6 digit master password i e 111111 followed by the key Passwords Default New Master 2 1 111111 I__I__I__I__I__I__I Main 2 2 1234 I__I__I__I__I Auxiliary 2 3 1234567 I__I__I__I__I__I__I__I Guard 2 4 123 I__I__I__I Timers Default New Strike relay 3 1 10 seconds I__I__I__I Alarm relay 3 2 10 seconds I__I__I__I Door ajar 3 4 20 seconds I__I__I__I Dures...

Страница 30: ...___I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I_____I_____I_____I_____I I_____I_____I_____I_____I I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I_____I_____I_____I_____I I_____I_____I_____I_____I I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I__...

Страница 31: ... the LCD will display a Time Out message and return to the normal greeting screen 4 The relay will be triggered and the system will disarm Depending on how the system is set up the strike may activate or deactivate 5 The LCD will return to the normal greeting display and the red LED will not flash When the door unlocks access is granted instantly When the door remains locked you must present your ...

Страница 32: ...rly Once the function is enabled in the system follow this procedure to use the duress function 1 Present your card at the reader skip this step if you are using mode 2 2 Key in your PIN or the main password if mode 2 immediately followed by the digit 9 Example 55559 followed by 3 The door will open normally access granted and the relay will activate for the pre set period of time How to use the D...

Страница 33: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 33 ...

Страница 34: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 34 ...

Страница 35: ......

Страница 36: ...ee US Canada 1 888 222 1560 Fax 1 978 731 7759 Web Site www Kantech com E mail techlink tycoint com 2003 Kantech Systems All rights reserved Specifications may be modified without notice Trademarks of Kantech Systems Printed in USA DN1445 0303 ...

Отзывы: