At the time of the burnout of the inlet sensor
TEMP. WARN. lamp (Red) is lighted and "---" is
flickered to HOT-AIR TEMP., "Tcc" to SETTING
TEMP. And, all the operation stop.
《
Main cause
》
Snapping of a wire of the inlet sensor
Snapping of a wire of the inlet sensor wiring
Miss of the inlet sensor wiring connector
《
Return method
》
Please order the repair after turning OFF the
breaker (NFB) of the this machine.
At the time of the inside temp. warning of the hot-air generator
TEMP. WARN. lamp (Red) is flickered and "OH" is
flickered to HOT-AIR TEMP., "ALM to SETTING
TEMP. And, It becomes blow operation condition.
《
Main cause
》
Establishment atmosphere temp. of the hot-air
generator is high.
Hot-air that leaked from the outlet flowed
backward to the control panel inside.
Influence of the furnace radiation temp. at the
time of the furnace upper part establishment.
《
Return method
》
Please stop operation by pushing STOP switch.
And, please disarm by turning OFF the breaker
(NFB) of this machine after inside temp. of the
hot-air generator dropped.
At the time of the inside SSC temp. warning of the hot-air generator (Only TSK-122, 132 200V)
TEMP. WARN. lamp (Red) is flickered and "SSc" is
flickered to HOT-AIR TEMP., "ALM" to SETTING
TEMP. And, It becomes blow operation condition.
《
Main cause
》
Establishment atmosphere temp. of the hot-air
generator is high.
Hot-air that leaked from the outlet flowed
backward to the control panel inside.
Influence of the furnace radiation temp. at the
time of the furnace upper part establishment.
Malfunction of the SSC cooling fan
《
Return method
》
Please disarm by pushing STOP switch after
inside temp. of the hot-air generator dropped.
Attention : Please block the source power supply (factory power supply) without fail when the
wiring is confirmed and readjusted at the time of abnormal.