8. Warning detection

Buzzer sounds at the same time as the warning detection about TSK-52HT, 62 - 132. Even

buzzer sound stops when warning was canceled by the return method of each warning.

8-1

Overheat

Overheat is detected in the case that the inside of the heater case became an abnormal high temp. Or,
burnout is detected in the case that the overheat sensor for the temp. control inside the heater case snapped.
And, the breaker (NFB) of this machine does trip and all the operation stop. (TSK-18 and Air volume
insufficient overheat prevention are only stopped the operation.)
At the time of overheat

Overheat lamp (Red) are lighted, and "nFb" is
flickered to HOT-AIR TEMP,  "Tcb" to SETTING

Main cause

Clogging of the inlet wire net and filter
Lock of the blower motor by the mixing of the
foreign substance
Exhaust outlet of furnace etc. is not secured
sufficiently
Resistance (pressure loss) of the outlet is big by
the adjacency of object work

Return method

Please remove the cause of overheat. And ,
source power supply and the breaker of this
machine are turned OFF at first and are turned
ON again after cooling sufficiently.  (TSK-18 is
only input of the factory power supply.)

At the time of overheat sensor burnout

Overheat lamp (Red) are flickered, and "---" is
flickered to HOT-AIR TEMP.. "Tcb" to SETTING

Main cause

Snapping of a wire of the overheat sensor
Snapping of a wire of overheat sensor wiring
Miss of the overheat sensor wiring connector

Return method

Please turn OFF the first power supply and
please order the repair.

At the time of air volume insufficient overheat prevention (Only TSK-52HT, TSK-62 - 132)

Overheat lamp (Red) are lighted, and "oVH" is
flickered to HOT-AIR TEMP., "Tcb" to SETTING

This operates when air volume decreased by some causes and the
heater inside temp. is exceeded the setting hot-air temp. There is the
exchangeability to the above overheat. But, which operates by use
situation.

Main cause

The same cause as the above overheat

Return method

Please remove the cause of overheat. And ,
source power supply and the breaker of this
machine are turned OFF at first and are turned
ON again after cooling sufficiently.  (TSK-18 is
only input of the factory power supply.)

Please do not operate again until the cause is removed when the overheat is operated.

-9-

Содержание TSK-23

Страница 1: ...nges this operation manual without taking our permission TSK 122 132 TSK 92 102 Operation manual Total edition Please read without fail before use Thank you very much for purchasing Hot air generator...

Страница 2: ...that was enclosed to the outlet and inlet Input terminal A1 A10 and output terminal B8 B10 is malfunctioned by the voltage is applied And output terminal B1 B7 is malfunctioned by the voltage more tha...

Страница 3: ...epare separately Recommendation cord Cab tire cable 100mm 2 Please use the commercial power supply 50 60Hz that has the sine wave like to the power supply of the hot air generator Please do not use th...

Страница 4: ...s by the temp of storage atmosphere drops in the winter season Hot air generator becomes freezing condition if this machine is stored in the condition that the condensation occurred and it becomes the...

Страница 5: ...N switch This is lighted when the operation condition was changed to the external sensor Hot air generator is operated with the external operation signal and external heater ON OFF signal by the switc...

Страница 6: ...ouple JISK Heatproof blower Hot air circulation type Breaker NFB Control panel Service terminal Eye bolt Hot air outlet Outlet temp sensor Thermocouple JISK Heatproof blower Hot air circulation type w...

Страница 7: ...and external heater input terminal E H is less than DC12V 3 6mA Please prepare the relay that has the contact capacity that can open and close this voltage Please change the external operation mode b...

Страница 8: ...case that the remote controller of the option is used For communication of the remote Please input DC4 20mA only TSK 122 and 132 4mA Heater output 0 20mA Heater output 100 Output terminal M3 20P The...

Страница 9: ...emp detection OFF OFF OFF OFF OFF OFF External sensor burnout OFF TSK 52HT 62 72 82 92 102 122 132 Action of the hot air generator Blow output Hot air output Temp warning Temp alarm Blower warning Ove...

Страница 10: ...f this machine are turned OFF at first and are turned ON again after cooling sufficiently TSK 18 is only input of the factory power supply At the time of overheat sensor burnout Overheat lamp Red are...

Страница 11: ...ter cooling sufficiently TSK 18 is only input of the factory power supply When the inlet temp exceeded the upper limit TEMP WARN lamp Red is lighted and present temp is lighted to HOT AIR TEMP Tcc is...

Страница 12: ...the time of the furnace upper part establishment Return method Please stop operation by pushing STOP switch And please disarm by turning OFF the breaker NFB of this machine after inside temp of the h...

Страница 13: ...s are confirmed And please communicate the display contents The position of the inverter panel differs by the machine type TSK 18 Back side of the control panel service terminal TSK 23 33 The inside o...

Страница 14: ...out fail when the wiring is confirmed and readjusted at the time of abnormal 8 4 Other warning Frequency warning Only TSK 52HT TSK 62 132 SYS is flickered to HOT AIR TEMP ALM to SETTING TEMP in the ca...

Страница 15: ...air generator is stopped at the time of the reverse connection of each temp sensor External sensor is included or perception of 15 C Only inside temp sensor is 10 C is flickered to HOT AIR TEMP displa...

Страница 16: ...sales kansaidennetsu co jp Inquiry regarding the hot air generator Homepage www kansaidennetsu co jp or E mail...

Отзывы: