Blower warning
All the operation of hot-air generator is stopped when the blower became overload, overcurrent, and lock.
At the time of the blower warning
BLOWER WARN. lamp (Red) is lighted and "InV" is
flickered to HOT-AIR TEMP., "ALM" to SETTING
TEMP.
《
Main cause
》
Wear of the bearing
Abnormal voltage (Voltage more than the rating)
Piping of many pressure loss
Opening the use of an extremely narrow nozzle
《
Return method
》
Abnormality is displayed to the inverter panel *
1
that was established inside. Please turn off the
breaker of this machine after the display contents
are confirmed. And, please communicate the
display contents.
The position of the inverter panel differs by the machine type.
TSK-18
Back side of the control panel service terminal
TSK-23
・
33
The inside of the back panel
TSK-42
・
52
The inside of the control panel (Please open the control panel and please confirm.)
TSK-52HT
The inside of the back panel
TSK-56
The inside of the control panel (Please open the control panel and please confirm.)
TSK-62
・
72
The inside of the back panel
TSK-82
The inside of the back panel
TSK-92
・
102
The inside of the back panel
TSK-122
・
132
The inside of the grid window of he control panel
Attention : Please block the source power supply (factory power supply) without fail when the
wiring is confirmed and readjusted at the time of abnormal.