background image

6. Name of every part

Control panel (All machine type community)





STOP switch

TIMER display

This is the stop switch of blow operation and hot-air operation,
and for the cancellation of timer operation.

Setting time of the timer is displayed. Time is reduced by time
counting.

HOT-AIR switch

HEATER lamp

Hot-air operation is started when the switch was pushed.

ON/OFF of the heater is displayed by illumination and
flickering.

BLOW switch

Blow operation is started when the switch was pushed.

TEMP. ALM lamp

OPERATION BY TIMER switch

This is lighted within the range of the temp. alarm setting value
in the case that temp. alarm setting is input.

Time that the operation is started is set up when the switch was
pushed. Please push HOT-AIR switch after setting.

EXT. CNTL lamp

STOP BY TIMER switch

This is lighted when the operation condition was changed to
the external control.

Time that the operation is stopped is set up when the switch
was pushed. Please push HOT-AIR switch after setting.

EXT. SENSOR lamp

EXT. RUN switch

This is lighted when the operation condition was changed to
the external sensor.

Hot-air generator is operated with the external operation
signal and external heater ON/OFF signal by the switch is
continued to push (about 2 seconds).

OVERHEAT lamp

This is lighted and the breaker (NFB) is become trip in the
case that the heater case inside became a abnormal high temp.

HOT-AIR TEMP. display

Outlet temp. is displayed. Temp. of the external sensor is
displayed by the operation condition is changed to the
external sensor.

TEMP. WARN. Lamp

Breaker (NFB) is become trip or bloe operation is become in
the case that discharge temp. became a high temp. or suction
temp. became over the permission temp. of the blower.

SETTING TEMP. display

Setting temp. of the outlet is displayed. Setting temp. of the
external sensor is displayed by the operation condition is
changed to the external sensor.

BLOWER WARN. Lamp

This is lighted when the blower became the overload and
operation stops.

AIR VOL. COTL display

PUSH TO TEST

Setting value of the air volume control (Frequency setting) is
displayed.

Breaker (NFB) is become trip by the button is pushed.

MODE switch

This is used in the case that the operation condition is changed. 

-4-

Содержание TSK-23

Страница 1: ...nges this operation manual without taking our permission TSK 122 132 TSK 92 102 Operation manual Total edition Please read without fail before use Thank you very much for purchasing Hot air generator...

Страница 2: ...that was enclosed to the outlet and inlet Input terminal A1 A10 and output terminal B8 B10 is malfunctioned by the voltage is applied And output terminal B1 B7 is malfunctioned by the voltage more tha...

Страница 3: ...epare separately Recommendation cord Cab tire cable 100mm 2 Please use the commercial power supply 50 60Hz that has the sine wave like to the power supply of the hot air generator Please do not use th...

Страница 4: ...s by the temp of storage atmosphere drops in the winter season Hot air generator becomes freezing condition if this machine is stored in the condition that the condensation occurred and it becomes the...

Страница 5: ...N switch This is lighted when the operation condition was changed to the external sensor Hot air generator is operated with the external operation signal and external heater ON OFF signal by the switc...

Страница 6: ...ouple JISK Heatproof blower Hot air circulation type Breaker NFB Control panel Service terminal Eye bolt Hot air outlet Outlet temp sensor Thermocouple JISK Heatproof blower Hot air circulation type w...

Страница 7: ...and external heater input terminal E H is less than DC12V 3 6mA Please prepare the relay that has the contact capacity that can open and close this voltage Please change the external operation mode b...

Страница 8: ...case that the remote controller of the option is used For communication of the remote Please input DC4 20mA only TSK 122 and 132 4mA Heater output 0 20mA Heater output 100 Output terminal M3 20P The...

Страница 9: ...emp detection OFF OFF OFF OFF OFF OFF External sensor burnout OFF TSK 52HT 62 72 82 92 102 122 132 Action of the hot air generator Blow output Hot air output Temp warning Temp alarm Blower warning Ove...

Страница 10: ...f this machine are turned OFF at first and are turned ON again after cooling sufficiently TSK 18 is only input of the factory power supply At the time of overheat sensor burnout Overheat lamp Red are...

Страница 11: ...ter cooling sufficiently TSK 18 is only input of the factory power supply When the inlet temp exceeded the upper limit TEMP WARN lamp Red is lighted and present temp is lighted to HOT AIR TEMP Tcc is...

Страница 12: ...the time of the furnace upper part establishment Return method Please stop operation by pushing STOP switch And please disarm by turning OFF the breaker NFB of this machine after inside temp of the h...

Страница 13: ...s are confirmed And please communicate the display contents The position of the inverter panel differs by the machine type TSK 18 Back side of the control panel service terminal TSK 23 33 The inside o...

Страница 14: ...out fail when the wiring is confirmed and readjusted at the time of abnormal 8 4 Other warning Frequency warning Only TSK 52HT TSK 62 132 SYS is flickered to HOT AIR TEMP ALM to SETTING TEMP in the ca...

Страница 15: ...air generator is stopped at the time of the reverse connection of each temp sensor External sensor is included or perception of 15 C Only inside temp sensor is 10 C is flickered to HOT AIR TEMP displa...

Страница 16: ...sales kansaidennetsu co jp Inquiry regarding the hot air generator Homepage www kansaidennetsu co jp or E mail...

Отзывы: