Troubleshooting
MULTICAL®
62 with flow sensor ULTRAFLOW®
24 is designed for quick and simple installation as well as
long and reliable operation at the water consumer.
Should you, however, experience an operating problem, the table below can be used for troubleshooting.
Repairing the meter, if needed, we recommend only to replace parts like battery and communication
modules. Alternatively the whole meter ought to be replaced.
Major repairs must be made by Kamstrup A/S.
Before sending in the sensor for repair or check, please use the error detection table below to help you
clarify the possible cause of the problem.
Symptom
Possible reason
Proposal for correction
The display value is not updated
Power supply missing
Change battery or check mains supply
No display function (empty
display)
Power supply missing
Change battery or check mains supply. Is
there 3.6 VDC on terminals 60(+) and 61 (-)?
If i fo
= 1
Supply voltage has been interrupted The info code is corrected automatically
No accumulation of volume (m
3
)
‘ead
info in the display
Check the error indicated by the info code
If i fo
= 16
Communication error or signal too
weak or wrong flow direction
There is air in the flow sensor?
Bleed the system and check the meter again.
Check that the flow direction matches the
arrow on the flow sensor
If i fo
= 2048
Flow sensor programmed with
wrong pulse figure
Please contact Kamstrup A/S
If i fo
= 4096
Signal too weak
There is air in the flow sensor? Bleed the
system and check the meter again.
If i fo
= 16384
Flow sensor mounted in wrong
direction
Check that the flow direction matches the
arrow on the flow sensor