12.1.1
MULTICAL® 62 Register IDs for water meter
ID
Register
Description
1003
DATE
Current date (YYMMDD)
68
V1
Volume register V1
84
VA
Input register VA
85
VB
Input register VB
1004
HR
Operating hour counter
113
INFOEVENT
Info event counter
1002
CLOCK
Current hour (hhmmss)
99
INFO
Info code register, current
74
FLOW1
Current flow
123
MAX FLOW1DATE/ÅR
Date of this ea s a .
124
MAX FLOW1/ÅR
This ea s a . alue
125
MIN FLOW1DATE/ÅR
Date of this ea s i .
126
MIN FLOW1/ÅR
This ea s
min. value
138
MAX
FLOW1DATE/MÅNED
Date of this o th s a .
139
MAX FLOW1/MÅNED
This o th s a . alue
140
MIN
FLOW1DATE/MÅNED
Date of this o th s i .
141
MIN FLOW1/MÅNED
This o th s i . alue
98
XDAY
Target date (reading date)
152
PROG NO
Program no. ABCCCCCC
153
CONFIG NO 1
Config no. DDDEE
168
CONFIG NO 2
Config. no. FFGGMN
1001
SERIE NO
Serial no. (unique number of each meter)
112
METER NO 2
Customer number (8 most significant digits)
1010
METER NO 1
Customer number (8 least significant digits)
114
METER NO VA
Meter no. of VA
104
METER NO VB
Meter no. of VB
1005
METER TYPE
Software edition
154
CHECK SUM 1
Software checksum
157
TOPMODUL ID
ID number of top module
158
BOTMODUL ID
ID number of base module
175
INFOHOUR
Error hour counter
234
IMPINa
l/imp. for VA
235
IMPINb
l/imp. for VB
239
V1HighRes
High resolution volume for input 1
12.1.2
Data protocol
Utilities and other relevant companies who want to develop their own communication driver for the
KMP protocol can order a demonstration program in C# (.net based) as well as a detailed protocol
description (in English).