7.3
Straight inlet
ULTRAFLOW® requires neither straight inlet nor outlet to meet the Measuring Instruments Directive (MID)
2004/22/EC and OIML R49. Only in case of heavy flow disturbances, before the meter, a straight inlet
section is necessary.
7.4
Installation example
The calculator can be mounted on top of the flow sensor s plastic housing; it must then be oriented as
shown in Figure 10.
If there is a risk of high humidity or low water temperature, in the flow sensor part, then the socket
extender (65-61-332) should be used, as shown in figure 11.
If the flow sensor part is mounted with plastic housing facing down, the calculator must be wall mounted,
as shown in Figure 12. Alternatively, the calculator can be mounted on the flow part with an angle fitting,
as shown in Figure 13.
Figure 12
Figure 13
MULTICAL® 62 mounted on a wall
MULTICAL® 62 mounted on ULTRAFLOW® 24,
by means of angle fitting 3026-252
Figure 11
Figure 10