MULTICAL® 62
TECHNICAL DESCRIPTION
Ka st up A/“ •
Technical
Des iptio •
5512-1036-GB_
D •
.2016
21
4.3.1
>EE< Configuration
The EE-code is not used for MULTICAL® 62 in connection with ULTRAFLOW®
a d is al a s
4.3.2
>FF< Input A (VA), pulse division >GG< Input B (VB), pulse division
MULTICAL® 62 has two extra optional pulse inputs, VA and VB, which are placed on the base modules
(see paragraph 9.8 for further details). The inputs can be configured via the FF and GG codes as shown
in the table below. In the absence of other information from the customer the inputs will be
configured as FF=24 and GG=24.
Input A
Terminal 65-66
Input B
Terminal 67-68
FF
Max. input
f
1Hz
GG
Max. input
f
1 Hz
Precounter
Wh/imp.
l/imp.
Measuring unit and decimal position
01
100 m³ h
01
100 m³ h
1
-
100
vol A/vol B (m
3
)
000000.0
02
50 m³ h
02
50 m³ h
2
-
50
vol A/vol B (m
3
)
000000.0
03
25 m³ h
03
25 m³ h
4
-
25
vol A/vol B (m
3
)
000000.0
04
10 m³ h
04
10 m³ h
10
-
10
vol A/vol B (m
3
)
000000.0
05
5 m³ h
05
5 m³ h
20
-
5.0
vol A/vol B (m
3
)
000000.0
06
2.5 m³ h
06
2.5 m³ h
40
-
2.5
vol A/vol B (m
3
)
000000.0
07
1 m³ h
07
1 m³ h
100
-
1.0
vol A/vol B (m
3
)
000000.0
24
10 m³ h
24
10 m³ h
1
-
10
vol A/vol B (m
3
)
00000.00
25
5 m³ h
25
5 m³ h
2
-
5.0
vol A/vol B (m
3
)
00000.00
26
2.5 m³ h
26
2.5 m³ h
4
-
2.5
vol A/vol B (m
3
)
00000.00
27
1 m³ h
27
1 m³ h
10
-
1.0
vol A/vol B (m
3
)
00000.00
40
1,000 m³ h
40
1,000 m³ h
1
-
1000
vol A/vol B (m
3
)
0000000
Pulse outputs without bounce damping (for meters with electronic pulse output):
71
100 m³/h
71
100 m³/h
1
-
100
vol A/vol b (m
3
)
000000,0
72
50 m³/h
72
50 m³/h
2
-
50
vol A/vol b (m
3
)
000000,0
73
25 m³/h
73
25 m³/h
4
-
25
vol A/vol b (m
3
)
000000,0
74
10 m³/h
74
10 m³/h
10
-
10
vol A/vol b (m
3
)
000000,0
75
5 m³/h
75
5 m³/h
20
-
5,0
vol A/vol b (m
3
)
000000,0
76
2,5 m³/h
76
2,5 m³/h
40
-
2,5
vol A/vol b (m
3
)
000000,0
77
1 m³/h
77
1 m³/h
100
-
1,0
vol A/vol b (m
3
)
000000,0
84
10 m³/h
84
10 m³/h
1
-
10
vol A/vol b (m
3
)
00000,00
85
5 m³/h
85
5 m³/h
2
-
5,0
vol A/vol b (m
3
)
00000,00
86
2,5 m³/h
86
2,5 m³/h
4
-
2,5
vol A/vol b (m
3
)
00000,00
87
1 m³/h
87
1 m³/h
10
-
1,0
vol A/vol b (m
3
)
00000,00
90
1000 m³/h
90
1000 m³/h
1
-
1000
vol A/vol b (m
3
)
0000000
FF
Max. Input
f
3 Hz
GG
Max. Input
f
3 Hz
Precounter
Wh/imp.
l/imp.
Measuring unit and decimal position
50
2500 kW
50
2500 kW
1
1000
-
EL A/EL B (kWh)
0000000
51
150 kW
51
150 kW
60
16.67
-
EL A/EL B (kWh)
0000000
52
120 kW
52
120 kW
75
13.33
-
EL A/EL B (kWh)
0000000
53
75 kW
53
75 kW
120
8.333
-
EL A/EL B (kWh)
0000000
54
30 kW
54
30 kW
240
4.167
-
EL A/EL B (kWh)
0000000
55
25 kW
55
25 kW
340
2.941
-
EL A/EL B (kWh)
0000000
56
20 kW
56
20 kW
480
2.083
-
EL A/EL B (kWh)
0000000
57
15 kW
57
15 kW
600
1.667
-
EL A/EL B (kWh)
0000000
58
7.5 kW
58
7.5 kW
1000
1.000
-
EL A/EL B (kWh)
0000000
59
750 kW
59
750 kW
10
100
-
EL A/EL B (kWh)
0000000
60
1250 kW
60
1250 kW
2
500
-
EL A/EL B (kWh)
0000000
70
25000 kW
70
25000 kW
1
10000
-
EL A/EL B (MWh)
00000.00
MULTICAL® 62 has no pulse output possibility via the base modules, only via the top modules.
See paragraph 11.1