Reset Function
8.7.1
Resetting the hour counter
As the hour counter, usually, is used to control if the meter has been in
operation mode, in the entire billing period (e.g. 1 year = 8760 hours),
the district heating supplier must always be informed about which
meters have had the hour counter reset.
The operational hour counter can only be reset via the front bottons.
Please, see 4.7
8.7.2
Resetting data loggers
Separate reset of data loggers, info loggers and max & min. loggers (without resetting the legal
registers) are only possible by means of METERTOOL.
8.7.3
Resetting all registers
Resetting all legal and non-legal registers
–
including all data loggers, info loggers, max & min. Loggers
–
can only be made by using METERTOOL, if the verification s
eal is oke a d the i te al Total
p og a
i g lo k
is short-circuited. As the verification seal hereby is broken, this can only be made at
an accredited laboratory.
Following registers are reset:
All legal and non-legal registers including all data loggers, info loggers, max & min. loggers (max. values
are set at zero, whereas min. values are set at 100000).
Afte eset . date
is set at 2000.01.01 and is then changed to current date/time of the PC used for
the task. Remember to check if date/t
i e te h i al sta da d ti e = i te
-
ti e
) is correct on the
PC, before the reset function is initiated.