TECHNICAL DESCRIPTION
MULTICAL® 62
Ka st up A/“ •
Technical
Des iptio •
5512-1036-GB_D1
•
.2016
26
4.7
Reset via the front keys
Via the the main key
and the sub-key
on MULTICAL® 62, a number of reset functions can be made.
4.7.1
Activate the reset-menu
The reset-menu is activated in the following way:
1)
Select the display reading that you wish to reset
2)
Remove the calculator from the base
3)
Wait until the display goes blank (up to 2.5 minutes). Meanwhile do not touch the
front keys
4)
While replacing the calculator on the base, press and hold the main key for approx. 8
seconds
5)
The reset-menu has now been activated
Having activated the reset menu, either the operation hour counter, the infoevent-counter or the
error hour counter will be displayed, depending on the register which was selected before activating
the reset menu.
When the reset menu has been
a ti ated,
will be displayed. It is not possible to change to any other
value. It is
o l possi le to
save the value = 0 in order to reset the register, or to leave the reset menu
without reset.
If a display register, which is not supported by the reset-menu, is selected, the meter will show the
normal display without activating the reset menu.
4.7.2
Exit the reset menu
When the operation hour counter, the info-event counter or the error hour counter displayes , hold
the main key for 5-6 seconds,
u til the OK
segment is displayed, and the display reverts to legal
reading.
If you wish to exit the reset menu without resetting any registers, then:
1)
Remove the calculator from the base
2)
Wait until the display goes blank (up to 2.5 minutes). Meanwhile do not touch the front keys
3)
Replace the calculator on the base without pressing the front keys
Allow some seconds for the meter to boot-up, without pressing the front keys. The normal display
register is now displayed and the reset menu is deactivated.
Note! If the front keys are not activated for 4 minutes, in the Reset menu
,
the menu will be
deactivated and the meter will automatically return to normal operation.
No data will be saved
i the ete s e o , u less the OK
segment is shown.