Operation Instructions for Air-to-water Heat Pump Split ECO HOME
Operation Instructions for Split Versati
9
SPLIT TYPE
heating, “
” also should be manually set to “
Without
” for getting higher leaving water temperature.
[Operation Instructions]
After “
” is set to “
Without
” (see 2.2.28), go to the FUNCTION page and locate “
T-water ctrl
.”, then,
, “
High temp
.” or “
Low temp.
”.
[Notes]
(a) When this setting is changed, the following parameters will return to the default values.
Full Name
Displayed Name
Default
Water out temperature for cooling
WOT-Cool
7°C/45°F[Low]
18°C/64.8°F[Normal]
Water out temperature for heating
WOT-Heat
45°C/113°F[High]
35°C/95°F[Normal]
Upper limit water-out temperature at the weather-dependent mode
for heating
Upper WT-Heat
48°C/118°F[High]
35°C/95°F[Normal]
Lower limit water-out temperature at the weather-dependent mode
for heating
Lower WT-Heat
40°C/104°F[High]
29°C/84°F[Normal]
(b) This setting will be memorized upon power failure.
2.2.5 Cool + Hot water
This compound mode enables the user to give priority to the “
Cool
” or “
Hot water
” mode depending on the
actual demand.
[Operation Instructions]
Go to the
FUNCTION
page and locate “
Cool+hot water
”, then, configure it through the Up/Down key
, “
Cool
” or “
Hot water
”.
[Notes]
(a) “
Hot water
” will take precedence only when “
Water tank
” is available, other it will tell “
Reserved
”.
(b) This setting will be memorized upon power failure.
2.2.6 Heat + Hot water
This compound mode enables the user to give priority to the “
Heat
” or “
Hot water
” mode depending on the
actual demand.
[Operation Instructions]
Go to the
FUNCTION
page and locate
Heat+hot water
, then, configure it through the Up/Down key
, “
Heat
” or “
Hot water
”.
[Notes]
(a) “
Hot water
” will take precedence only when “
Water tank
” is available, other it will tell “
Reserved
”.
(b) This setting will be memorized upon power failure.
2.2.7 Quiet
This function can be activated when the running noise is too high.
[Note]
when this function is activated, frequency of both the compressor and the fan will go down and also the capacity
of the unit will correspondingly decrease.
[Operation Instructions]
Go to the
FUNCTION
page and locate “
Quiet
, “
On
” or
“
Off
”.
[Notes]
(a) It can be set to “
On
” or “
Off
” no matter if the unit is in operation or not.
(b) Once it is activated, it should be deactivated manually or by
Quiet Timer
.
(c) This setting will be memorized upon power failure.