■ Procedures following a fault of the refrigerated dryer:
─ Compressed air quality has priority
Call KAESER Service immediately
■ Procedures following a fault of the refrigerated dryer:
─ Compressed air quantity has priority,
Activate fault mode without refrigerated dryer
➤ It is mandatory to follow the procedures indicated according to the priorities established for the
compressed air quality or compressed air quantity!
7.7.1 Setting the CLOCK mode
You may select either CONTINUOUS or CLOCK mode for controlling the refrigerated dryer.
If the CLOCK setting is used, the refrigerated dryer is shut-down under timing control whenever
compressed air is not required.
The operating temperature in the refrigerated dryer is kept constant within narrow limits under this
method of control by cycling the refrigerant circulation.
Precondition Access level 2 is activated.
1. In operating mode, switch to the main menu with the «Enter» key.
2. Select the
< Configuration ➙ Refrigeration dryer > menu.
The
< Refrigeration dryer > menu is displayed.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
5.9 Refrigeration dryer
Menu
Control mode
Active line
Compressor ready:
Continuous
Compressor Clk/RC/RB off:
off
·········
3. Press «DOWN» twice.
The
Continuous line is displayed as being active.
4. Press «Enter» to switch into setting mode.
Display flashes.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
5.9 Refrigeration dryer
Menu
Control mode
Compressor ready:
Continuous
Active line
Compressor Clk/RC/RB off:
off
·········
5. Press «UP» once.
The
Clock mode is displayed.
7
Initial Start-up
7.7
Activating the settings for the refrigerated dryer
78
Service manual Controller
SIGMA CONTROL 2 SCREW FLUID 1.1.3
9_9450 03USE
Содержание ESD 352 SFC
Страница 5: ......
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 38: ...Original instructions KKW SESD 2 02 en 05 ESD_2C_10357405_10 000_00 KKW SSC 2 02 05 20130903 095638...
Страница 42: ...Contents iv Service Manual Screw Compressor ESD 442 14 bar abs SFC SIGMA CONTROL 2 ESD_2C_10357405_10 LIN_00 E...
Страница 171: ...KKW SSC 2 03 en 01 BA SIGMA CONTROL FLUID KKW SSC 2 03 01 20130805 113302...
Страница 173: ......
Страница 175: ...Contents ii Quick user guide Controller SIGMA CONTROL 2 SCREW FLUID 1 1 3 9_9450 03 USE...
Страница 215: ...Contents iv Service manual Controller SIGMA CONTROL 2 SCREW FLUID 1 1 3 9_9450 03USE...
Страница 217: ...List of Illustrations vi Service manual Controller SIGMA CONTROL 2 SCREW FLUID 1 1 3 9_9450 03USE...
Страница 392: ...KKW GBASE 1 00 en ERSATZTEILE 10357405_10 ESD 2C 20130903 115349...
Страница 394: ...Contents ii Spare parts Screw compressor ESD 442 SFC 14 bar ESD 2C 1204 1205 No TTL ESD_2C_10357405_10_00 E...
Страница 396: ...List of Illustrations iv Spare parts Screw compressor ESD 442 SFC 14 bar ESD 2C 1204 1205 No TTL ESD_2C_10357405_10_00 E...
Страница 398: ...List of Tables vi Spare parts Screw compressor ESD 442 SFC 14 bar ESD 2C 1204 1205 No TTL ESD_2C_10357405_10_00 E...