background image

➤ Keep to inspection intervals in accordance with the Ordinance on Industrial Health and Safety

with maximum intervals as laid down in §16:

Inspection

Inspection interval

Inspection authority

Equipment inspec‐

tion

Before commissioning

Approved supervisory body.

Internal inspection Every 5 years after commissioning

or the last inspection

Contact an authorized KAESER serv‐

ice representative.

Strength test

Every 10 years after commissioning

or the last inspection

Contact an authorized KAESER serv‐

ice representative.

Tab. 41 Inspection intervals according to Ordinance on Industrial Health and Safety

Checking the lifting point

The user is responsible for ensuring that the machine's lifting point and fixings are inspected ac‐

cording to national regulations for wear and damage.
➤ Have lifting point checked.

Lifting point is not in order: The machine must not be transported by crane. Have the machine

repaired immediately.

3.5  Dangers

Basic instructions

The following describes the various forms of danger that can occur during machine operation.
Basic safety instructions are found in this service manual at the beginning of each chapter in the

section entitled 'Safety'.
Warning instructions are found before a potentially dangerous task.

3.5.1  Safely dealing with sources of danger

The following describes the various forms of danger that can occur during machine operation.

Exhaust fumes

Exhaust gases from combustion engines contain carbon monoxide, a color- and odor- less but

highly toxic gas. The inhalation of minute quantities can be lethal.

Furthermore, diesel exhaust contains soot particles, some of which are noxious.
➤ Do not inhale exhaust fumes.
➤ Park the machine in such a manner that the exhaust cannot blow towards the operators.
➤ Never use the machine in enclosed spaces, only in the open.

Fire and explosion

Spontaneous ignition and combustion of fuel can result in serious injury or death.
➤ Do not allow open flames or sparks at the place of use.
➤ Do not smoke while refueling.
➤ Never refuel the machine when it is running.
➤ Do not allow fuel to overflow.

3

Safety and Responsibility

3.5

Dangers

20

Operator Manual    Portable Rotary Screw Compressor  
MOBILAIR M58utility  SIGMA CONTROL SMART

No.: 901779 08 USE

Содержание MOBILAIR M58utility

Страница 1: ...Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE Manufacturer KAESER KOMPRESSOREN SE 96410 Coburg PO Box 2143 GERMANY Tel 49 0 9561 6400 Fax 49 0 9561 640130...

Страница 2: ...Original instructions KKW M58U 2 08 en Z1 SBA MOBILAIR 20220512 154416...

Страница 3: ...8 2 5 2 Compressed air outlet 8 2 5 3 Safety valves 8 2 5 4 Temperature 9 2 5 5 Cooling oil recommendation 9 2 5 6 Cooling oil charge quantity 10 2 6 Engine 11 2 6 1 Engine specification 11 2 6 2 Oil...

Страница 4: ...stem 44 4 7 3 Regeneration of the diesel particulate filter 45 4 8 Sealed floor pan 46 4 9 Options 46 4 9 1 Air treatment options 47 4 9 2 Auxiliary electrical systems 49 4 9 3 Low temperature equipme...

Страница 5: ...g the machine after operation 78 8 5 1 Cleaning the exterior of the machine 79 8 5 2 Cleaning the interior of the machine 80 8 6 Operating the options 82 8 6 1 Operating the machine with the Start sto...

Страница 6: ...Fit the flexible pipe connection 143 10 7 Cleaning the cooler 144 10 7 1 Cleaning the compressor cooler and engine radiator 144 10 7 2 Cleaning the compressed air after cooler 145 10 8 Checking screw...

Страница 7: ...200 12 4 3 Draining condensate 200 12 4 4 Removing filters filter elements 201 12 4 5 Disposing of the machine 201 13 Annex 13 1 Identification 202 13 1 1 Identification of the machine 202 13 1 2 Iden...

Страница 8: ...Contents vi Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 9: ...opping procedure 67 Fig 28 Battery isolating switch 68 Fig 29 Control line shut off valve 70 Fig 30 Quick access adjustment compressed air output pressure 71 Fig 31 Setting the compressed air discharg...

Страница 10: ...ible pipe connection 143 Fig 66 Cleaning the compressor cooler and engine radiator 145 Fig 67 Cleaning the compressed air after cooler 146 Fig 68 Tool lubricator maintenance 152 Fig 69 Cleaning the co...

Страница 11: ...ns 11 Tab 28 Engine oil recommendation 12 Tab 29 Initial engine oil quantity 12 Tab 30 Water quality parameters for cooling water 13 Tab 31 Initial filling of engine water cooler 14 Tab 32 Fluid volum...

Страница 12: ...Advise others that the machine is being serviced 96 Tab 70 Maintenance messages and required actions 97 Tab 71 Maintenace tasks on the machine after commissioning 99 Tab 72 Maintenance intervals and r...

Страница 13: ...e you provide the data from the nameplate when ordering documents 1 3 Copyright This operator manual is copyright protected Queries regarding use or duplication of the documen tation should be referre...

Страница 14: ...Warning notices for damages are identified by their signal term Signal term Meaning Consequences of ignoring the warning NOTE Warns of a potentially dangerous situation Damage to property is possible...

Страница 15: ...ture separator Option codes used in this service manual are explained in chap ter 2 3 Information referring to potential problems are identified by a question mark The cause is named in the help text...

Страница 16: ...n number remains associated with the machine throughout the entire dura tion of its service life The vehicle identification number is stamped into the bodywork of the ma chine Further information For...

Страница 17: ...ion ec Tool lubricator Option Option code Available Tool lubricator ec Tab 6 Tool lubricator option 2 3 3 Option fc Air distributor Option Option code Available Separated compressed air lines downstre...

Страница 18: ...ries od Tab 10 Automatic engine start stop 2 3 7 Option oc GSM GPS unit Option Option code Available GSM GPS unit oc Tab 11 GSM GPS unit 2 4 Machine without options 2 4 1 Sound pressure level Sound pr...

Страница 19: ...bf in 354 620 929 1416 2832 4868 Surface finish zinc flake coating matte Standards based on VDI 2230 Tab 14 Torques for M10 M24 screws 2 4 2 2 Torque cover fixing screws oil separator tank Recommended...

Страница 20: ...e with ISO 1217 2009 Annex D Installation of the machine within the EU Maximum working pressure psi 100 145 SIGMA airend 265 260 Volumetric flow cfm 180 154 Tab 17 Working pressure an volumetric flow...

Страница 21: ...for general applications SIGMA FLUID MOL S 460 S 570 Description Mineral oil Silicone free synthetic oil Synthetic oil Application Standard oil for all appli cations except in con nection with food pr...

Страница 22: ...ions where the compressed air may come into contact with foodstuff Approval USDA H 1 NSF Approved for the manufacture of food packaging meat and poultry processing and other food process ing applicati...

Страница 23: ...ion of the machine outside of the EU Tab 26 Kubota V 2403 CR Engine specifications Carbon dioxide emissions Definition of CO2 emissions CO2 emissions are the mass of carbon dioxide produced when subst...

Страница 24: ...ways ensure the prescribed lubricating oil quality when selecting the viscosity class Ambient temperatures F Viscosity class 77 SAE 30 SAE 10 W 30 SAE 15 W 40 32 77 SAE 10 W 30 SAE 15 W 40 4 104 SAE 1...

Страница 25: ...by contamination 2 6 4 Engine coolant recommendation In fluid cooled engines the cooling fluid must be treated and monitored to prevent engine damage Water quality An important factor for treating the...

Страница 26: ...he coolant cooler is filled with a mixture of the following liquid components Components Description Percentages vol Corrosion inhibitor antifreeze KAESER FLUID ENGINE ANTIFREEZE Glysantin G40 50 Wate...

Страница 27: ...on Components Characteristics Abbreviation da After cooler Centrifugal separa tor cool and condensate free A ec Tool lubricator Lubricated E Tab 35 Interrelation between compressed air treatment and c...

Страница 28: ...equency Hz 60 Supply cable cross section AWG Cu multi core 3 x 16 User s fusing A 16 Tab 37 Power supply details Coolant pre heating diesel engine Coolant pre heater Value Voltage V 240 Power W 500 Ta...

Страница 29: ...eature Specification Type CANlink mobile 5 Tab 40 GSM GPS unit 2 Technical Data 2 7 Options No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 17...

Страница 30: ...s listed in this service manual Operate the machine only within its performance limits and under the permitted ambient condi tions Do not use compressed air for breathing purposes unless it is specifi...

Страница 31: ...ansport personnel possess the following qualifications are of legal age are familiar with and adhere to the safety instructions and sections of the service manual rele vant to transporting are trained...

Страница 32: ...er that can occur during machine operation Basic safety instructions are found in this service manual at the beginning of each chapter in the section entitled Safety Warning instructions are found bef...

Страница 33: ...he following information concerns work on components that could be under pressure Wait until the compressor has automatically vented Check the pressure gauge it must read 0 psig Then open an outlet va...

Страница 34: ...ate measures to prevent sparks or heat from igniting oil vapors or parts of the machine Noise The enclosure absorbs the machine noise to a tolerable level This function will be effective only if the b...

Страница 35: ...protective clothing examples Safety work wear Protective gloves Safety boots Eye protection Ear protection 3 5 2 1 Transport The weight and size of the machine require safety measures during its tran...

Страница 36: ...p of heat from the hot exhaust gases can damage the machine Ensure accessibility so that all work on the machine can be carried out without danger or hin drance Do not operate in areas in which there...

Страница 37: ...s of the EMERGENCY STOP push button of parts that require monitoring Pay particular attention to cleanliness during all maintenance and repair work Cover compo nents and exposed openings with clean cl...

Страница 38: ...l and their responsibilities Give clear instructions on reporting faults and damage to the machine Give instructions on fire reporting and fire fighting measures 3 5 4 Danger areas The table gives inf...

Страница 39: ...Location of safety signs outside Location Symbol Meaning 265 Injury and or machine defects caused by improper use Maintenance should be performed by properly trained personnel only Read and understan...

Страница 40: ...s in use 440 Compressed air quality Injury and or contamination can result from breathing compressed air Contamination of food can result from using untreated compressed air for food processing Never...

Страница 41: ...zen Due to risk of explosion please ensure that you bring the battery up to a temperature of at least 60 F before attempting a jump start 303 Fire or explosion caused by refueling Severe injury or dea...

Страница 42: ...an for purposes of maintenance repair or replacement of any devices or element of design incorporated into any new com pressor for the purpose of noise control prior to its sale or delivery to the ult...

Страница 43: ...y with skin cleaner then with soap and water Contaminated clothing should be intensively cleaned before reuse If inhaled Fuel and oil vapours impair breathing Clear the respirator tract from fuel or o...

Страница 44: ...d various modules are designed according to applicable regulations and are sub mitted for approval procedures by the relevant authorities where applicable Concerned modules include Compressor drive mo...

Страница 45: ...be operated used and maintained in accordance with instruction provided to the end user Do not intentionally manipulate the engine management of the drive engine or operate it im properly or carry out...

Страница 46: ...g against touching Cooling air flow The bodywork is not suitable for the following uses Walking on standing or sitting on Use as resting place or storage of any kind of load Pinch hazard Severe injuri...

Страница 47: ...9 Oil separator tank 10 Control valve 11 Compressor air filter 12 Engine air filter Fig 5 Right side panels removed 13 Lifting eye 14 Safety valve 15 Inlet valve 16 Airend 17 Fuel tank 18 Compressor...

Страница 48: ...ith water trap 26 Battery isolating switch 27 Operating panel 28 Air outlet valves 29 Fuel fine filter 31 EMERGENCY STOP push button 4 Design and Function 4 2 Machine structure 36 Operator Manual Port...

Страница 49: ...ompressor air filter 12 Engine air filter 13 Lifting eye 16 Airend 17 Fuel tank 18 Oil cooler 21 Exhaust silencer 22 Air distributor 23 Instrument panel cover Fig 8 Underside of the machine 27 Front 2...

Страница 50: ...rend is driven by an internal combustion engine 15 Cooling oil is injected into the airend It lubricates moving parts and forms a seal between the ro tors themselves and between them and the airend ca...

Страница 51: ...DLE The inlet valve is closed The control valve opens allowing pressure in the oil separator tank to be applied to the inlet valve Compressed air then flows in a closed circuit through the airend the...

Страница 52: ...onal controller optionally adjusta ble 27 Venting valve 62 Combined auxiliary valve directional con trol valve 4 5 Safety devices 4 5 1 Monitoring functions with shut down The SIGMA CONTROL SMART moni...

Страница 53: ...dental contact 4 5 3 Battery isolating switch The battery isolating switch disconnects the battery completely from the machine s electrical sys tem electronic controller protection fire protection bat...

Страница 54: ...nowledges resets mainte nance tasks Returns to the superordinate menu item quick touch Closes the menu press for at least two seconds 4 Key LOAD IDLE Toggles the compressor between LOAD and IDLE opera...

Страница 55: ...the system controller SIGMA CONTROL SMART In addition to monitoring the engine and exhaust gas treatment the engine control unit ECU also monitors itself Any faults or malfunctions are stored as faul...

Страница 56: ...exhaust gas emissions of the machine Fig 13 Principle of treatment devices 1 Engine control unit ECU a Common rail system 2 Engine block 3 Exhaust gas return valve EGR 4 Inlet throttle 5 Intercooler 6...

Страница 57: ...or passive continuous regeneration is a sufficient ratio of nitrogen oxides and soot in the engine s exhaust gas Definition of nominal filter load The engine control unit internally monitors the soot...

Страница 58: ...to capture small leaks in the vicinity of endangered components is fitted with de watering lines closed with plugs These lines must be tightly re closed af ter performing any cleaning work Is equipped...

Страница 59: ...moisture carried in the air is removed in the aftercooler This condensate mixed with oil particles has to be drained by a separator 4 9 1 2 Option da Centrifugal separator A centrifugal separator is...

Страница 60: ...air for this purpose A metering valve on the lubricator regulates the amount of oil in the compressed air minimum oil to lubricate the tools and prevent corrosion more oil for cleaning and to prevent...

Страница 61: ...he user s power socket Cooling water heater for diesel motor The motor s coolant should be pre heated in order to protect the motor at low temperatures A cool ing water pre heating system is installed...

Страница 62: ...he operation in fire hazard areas the machine is equipped with the following accessories Spark arrestor 4 9 4 1 Option la Spark arrestor Sparks in exhaust fumes represent a considerable risk in enviro...

Страница 63: ...r 4 9 6 Option oc GSM GPS unit The machine is equipped with a GSM GPS unit This is equipped with a SIM card and provides fleet management capability for the customer The GSM GPS unit comprises GSM mod...

Страница 64: ...to explosion protection are applied Keep suitable fire extinguishing agents on hand and ready for use Ensure that required ambient conditions are maintained Required ambient conditions may be A specif...

Страница 65: ...machine feet anti vibration mountings 1 Follow the vehicle manufacturer s loading guidelines for safe operation and transportation 2 Ensure there is enough free space around and above the machine 3 E...

Страница 66: ...ithin reach at all times 4 Ensure there is enough free space around and above the machine 5 Keep air inlet and outlet openings free of obstructions so that the cooling air can flow freely through the...

Страница 67: ...machine for visible and hidden transport damage 2 Inform the carrier and the manufacturer in writing of any damage found 6 3 Mounting the machine on the truck platform For safe footing fix the machine...

Страница 68: ...e thread of the adjustable machine mount or rubber pad 6 Tighten both hex head bolts 6 3 2 Mounting the machine on the truck platform Precondition bolt down machine feet are attached to the machine 1...

Страница 69: ...ery charger is designed for operation in an industrial environment with a dedicated power supply network separated from the public power supply network by a transformer or a generator The operator mus...

Страница 70: ...2 Details of dangers and their avoidance are found in chapter 3 5 7 2 Before initial start up or recommissioning Incorrect or improper commissioning can cause injury to persons and damage to the mach...

Страница 71: ...ian Tab 46 Measures for re commissioning the compressor after a long period of storage or de commissioning 7 3 Checking installation and operating conditions Check and confirm all the items in the che...

Страница 72: ...harged it can be started with the battery of another vehicle or engine driven machine Material Jumper cables Fire and explosion hazard High currents can flow if the battery is short circuited A shorte...

Страница 73: ...serve the instructions provided with the battery jumper cables Keep jumper cables away from rotating parts Avoid short circuits due to incorrect poling and or bridging with tools Do not bend over the...

Страница 74: ...minutes This is important in particular for fully discharged batteries The battery will pick up only little current in the beginning and has a high internal resistance Any voltage peaks occurring in t...

Страница 75: ...perating side with open operating panel 2 Device connector plug for auxiliary electrical systems 3 Power cable 1 Danger of fatal injury from electric shock Serious injury or death can result from a sh...

Страница 76: ...hocks burns or death Work on electrical equipment may only be carried out by authorized electricians Safe working with compressed air tools and hoses Open pressurized compressed air hoses move erratic...

Страница 77: ...d in chapter 3 5 8 2 Starting and stopping Precondition No personnel are working on the machine Service doors and panels are locked Fig 24 Starting instruments 1 Instrument panel cover with sticker gi...

Страница 78: ...g instructions Brief instructions containing symbolic information on starting and stopping are attached at the in side of the instrument panel cover Starting sequence Fig 26 Brief instructions on star...

Страница 79: ...STOP pushbutton 1 EMERGENCY STOP pushbutton locked out The machine cannot be stopped quickly in an emergency Check the function of the EMERGENCY STOP pushbutton Do not operate the machine if the EMER...

Страница 80: ...re engine damage Do not use cold start sprays Preparing the start 1 Open the control panel cover 2 Switch the Controller ON OFF key to ON The controller boots up and the operating indicators appear on...

Страница 81: ...ation Precondition Specified value for the engine coolant temperature ECT is attained Press LOAD IDLE key The machine switches to LOAD operation and is ready to deliver compressed air Precondition Spe...

Страница 82: ...achine running The pressure can only be set at lower than the nominal working pressure of the machine You can adjust the settings in increments of 0 1 bar or 1 psi The adjustment is displayed Danger f...

Страница 83: ...d air discharge pressure is immediately active and remains saved 3 Press Enter The frame disappears 4 Press Enter Jump back to the menu bar the Main menu symbol receives a black background Access via...

Страница 84: ...pt stopping of the engine under load can cause a fault or damage to the turbo charger Use the controller to shut down the machine as normal do not use the EMERGENCY STOP push button to save time Switc...

Страница 85: ...ngine control unit has completed save process 2 Shut down the controller Switch off the Controller ON OFF key Shutting down the machine If the machine is not to be used again the Battery isolating swi...

Страница 86: ...or sparks Do not allow fuel to spill or overflow Do not smoke Follow all instructions carefully 8 3 1 Use the specified fuel type In the worst case scenario use of the incorrect fuel type in a modern...

Страница 87: ...must be filled exclusively with liquid fuel of the correct type and the recommended specification A label placed on the fuel tank in the vicinity of the filler port indicates the correct fuel type se...

Страница 88: ...is standing level The machine has cooled down The enclosure is open All compressed air consumers are disconnected the discharge valves are open the machine is fully vented the pressure gauge reads 0 p...

Страница 89: ...or overflow 5 Fill the tank to the maximum fill level marking Sufficient expansion volume remains 6 Remove the funnel 7 Close the filler port with the cap Dispose of any spilled fuel and fuel contami...

Страница 90: ...cknowledged by restarting the controller Precondition Machine shut down Fault is rectified Switch on the Controller ON OFF key The acknowledged message is deleted The machine can be started Further in...

Страница 91: ...l and internal cleaning of the machine Deploy the extension pole of the high pressure washer in order to maintain the necessa ry distance from the object being cleaned Keep the extension pole of the h...

Страница 92: ...approximately 30 inches Fan jet nozzles approximately 12 inches Dirt blasters approximately 12 inches 1 Do not use jet water to clean plug sockets 2 Deploy the extension pole of the high pressure was...

Страница 93: ...mponents and sensitive display instruments Do not direct jet water at electrical components 2 Do not direct jet water at the starter control box or sensitive display instruments 3 Do not direct jet wa...

Страница 94: ...ode as usual during normal operation The respective current setting is saved The battery can deplete if the controller is continuously switched on readiness for automatic machine run The starting volt...

Страница 95: ...Shutting down the machine When the compressed air demand via the remote contact of the master controller stops the ma chine shuts down as follows 1 Machine switches to run on phase The engine runs at...

Страница 96: ...witched off Tool lubricator filled with oil Fig 34 Setting the tool lubricator 1 Shut off valve I open 0 closed 2 Metering knob Open the access door Adding lubricating oil 1 Open the shut off valve 2...

Страница 97: ...on Fill the tool lubricator with suitable oil see chapter 10 13 1 Shutting off lubricating oil 1 Close the shut off valve 2 Close the door 8 6 3 Option ba Using the low temperature equipment Start the...

Страница 98: ...the controller factory settings and individu al equipment with which the machine is provided 9 2 1 Alarm messages on the controller machine off Fault with automatic deactivation of the machine You mus...

Страница 99: ...150 Fault ECU other faults Have it checked X X 1151 Fault ECU SCS com munication Have it checked X X 1160 Fault rail pressure sen sor Have it checked X X 1161 Fault speed sensor Have it checked X X 11...

Страница 100: ...lt PLC memory er ror Have it checked X 1302 Fault PLC HMI commu nication Have it checked X 1303 Fault PLC temperature high Check operating condi tions Allow the machine to cool down 5 2 1304 Fault PLC...

Страница 101: ...d troubleshooting in General faults 9 2 2 Warning messages on the controller The machine is not shut down In the case of an over temperature warning the machine switches automatically to IDLE mode to...

Страница 102: ...Specialized workshop KS KAESER SERVICE DPF Diesel particulate filter ECU Electronic Control Unit UM SCS Separate user manual for the SIGMA CONTROL SMART controller Tab 56 Warning messages and measure...

Страница 103: ...lace starter X Engine electrical fault Have it epaired replaced X Fuel tank empty Fill the fuel tank Air pockets in fuel line between fuel tank and injection pump Bleed the fuel line see chap ter 10 4...

Страница 104: ...e chapter 10 4 3 Fuel line broken Have it replaced X Engine electrical fault Have it repaired replaced X SIGMA CONTROL SMART con troller faulty Arrange for it to be repaired replaced X SW Specialist W...

Страница 105: ...or replaced if necessary X Inlet valve not opening or only opening partially Repair or have replaced if nec essary X Pressure gauge indicating false pressure Have repaired or replaced if necessary X...

Страница 106: ...ot workingl Have repaired or replaced if necessary X Working pressure too high pro portional controller maladjus ted Reset to the permissible value or have replaced X Oil separator cartridge heavily c...

Страница 107: ...Remedy Where can I get help SW KS Defective non return function of the inlet valve Repair or have replaced if nec essary X SW specialised workshop KS KAESER SERVICE Tab 67 Alarm Oil flows from the co...

Страница 108: ...ning Don t activate the machine Warning The machine is being serviced Tab 69 Advise others that the machine is being serviced Before switching on make sure that nobody is working on the machine all pr...

Страница 109: ...of the service task are displayed below Upon maintenance the maintenance interval counter must be reset Read the message code from the controller s display 10 2 1 Evaluating the maintenance message D...

Страница 110: ...al components with average operating conditions In adverse conditions e g oil and filter changes perform maintenance work at shorter intervals Adverse conditions are e g poor fuel quality high low tem...

Страница 111: ...clamps If necessary tighten the hose clamps X KS SW E50 after the first 50 operating hours KS contact KAESER SERVICE SW contact specialised workshop Tab 71 Maintenace tasks on the machine after commis...

Страница 112: ...r filter X 10 4 2 Check engine air filter mainte nance indicator X 10 4 2 Check engine oil level X 10 4 4 Clean engine air filter X 10 4 2 Replace the engine oil X 10 4 6 Replace the engine oil filter...

Страница 113: ...stem for leaks including the exhaust gas after treatment components X Service the exhaust gas after treatment components X 10 5 Arrange for the DPF to be cleaned X KUBOTA Have all lines to and from th...

Страница 114: ...ave excess temperature safety shutdown tested for proper func tion X 10 12 3 KS Bodywork chassis Check screw connections X 10 8 Service rubber sealing strips X 10 9 Arrange for crane suspension to be...

Страница 115: ...n the tables must additionally be carried out every 6 months if the annual operational performance is more than 500 operational hours Option Task Daily A250 A500 See chapter Note Option ec tool lubric...

Страница 116: ...hine is standing level The machine is fully vented the pressure gauge reads 0 psig The machine has cooled down All compressed air consumers are disconnected and the air discharge valves are open Risk...

Страница 117: ...tween the minimum and maximum marks when the engine is cool Fig 35 Checking the coolant level 1 Coolant level A Maximum mark FULL B Minimum mark LOW 2 Filler neck with cap 3 Overflow 4 Coolant expansi...

Страница 118: ...Engine housing fracture Check coolant Protect the coolant against freezing Replenish immediately if necessary 2 Use the coolant tester as instructed by the manufacturer to test the coolant Concentrati...

Страница 119: ...transfer properties deteriorate beyond this point 10 4 1 4 Filling refilling the coolant In order to ensure optimum frost corrosion protection and prevent the build up of deposits sludge in the coolin...

Страница 120: ...release coupling 7 Shut off valve ball valve I Open 0 Closed 8 Rear view air exhaust louvre box removed 1 Loosen and remove the coolant expansion tank filler cap 2 Remove the air exhaust louvre box fr...

Страница 121: ...lter elements is mandatory Operating the engine without an air filter insert installed is not permitted Do not use filter elements with damaged pleats or seals The use of an unsuitable air filter can...

Страница 122: ...zone Fig 39 Engine air filter maintenance 1 Maintenance indicator 2 Red zone indicator scale 3 Indicating piston of the maintenance indi cator 4 Reset knob of the maintenance indicator 5 Filter elemen...

Страница 123: ...the filter housing the cap and sealing faces with a damp cloth 4 Cleaning the filter element Use dry compressed air 5 bar at an angle to blow dust from the element from inside to outside until no more...

Страница 124: ...in accordance with environmental protection regulations 10 4 3 Fuel system maintenance Make sure no dirt enters the fuel system during maintenance Clean components and their sur roundings before dism...

Страница 125: ...ite a full tank bleed the fuel system Fig 43 Bleeding the fuel system 1 Fuel pre filter with integrated water trap 2 Bleed screw 3 Manual fuel pump 1 Place a receptacle beneath the fuel pre filter hou...

Страница 126: ...filter cartridge The water trap is connected by a sensor to the controller If the water in the trap reaches a set lev el the controller displays a warning The display indicates water in the fuel filte...

Страница 127: ...drain wa ter and contamination 3 Close the draining stopper 4 Close the access door Warning must be acknowledged after the water trap has been emptied Precondition The water trap is drained Confirm t...

Страница 128: ...Check the seal of the draining stopper Gasket damaged replace gasket 8 Screw the draining stopper to a new filter cartridge 9 Clean the sealing faces of the filter cartridge and filter head with a dam...

Страница 129: ...r cartridge is seated tightly to turn ap proximately 5 Turn on the battery isolating switch 6 Close the access door The fuel system must be bled after the filter cartridge has been changed Dispose of...

Страница 130: ...nimum level or is below the mark Replenish engine oil 4 Attach the panel The marked maximum oil level should not be exceeded in order for the level of oil in the crankcase not to reach the crankshaft...

Страница 131: ...e left rear panel 5 After approximately 5 minutes Check the engine oil level Low oil level Replenish engine oil 6 Visually inspect for leaks 7 Attach the panel 10 4 6 Changing the engine oil The engin...

Страница 132: ...sump 6 Engine block 7 Oil filler with filler cap 1 Open the access door and remove the left rear panel 2 Remove the filler cap from the oil filler 3 Place the oil receptacle below the drain point 4 Un...

Страница 133: ...to unscrew the filter 3 Engine block 1 Remove the left rear panel 2 Prepare a receptacle 3 Use a filter wrench to loosen and unscrew the filter Catch any escaping oil 4 Carefully clean sealing surface...

Страница 134: ...disconnected and the air outlet valves are open The battery isolating switch is turned off Beware of rotating pulleys and moving belts There is danger of serious injury from pinching Never check the...

Страница 135: ...the battery isolating switch 3 Attach the panel 10 4 8 2 Checking belt tension Check belt tension when they are warm not hot to avoid length variations through temperature The belt tension can be chec...

Страница 136: ...e lever between the alternator and engine block 3 Gently push the alternator in the direction of the arrow outwards using the lever until the drive belt is tensioned 4 Re tighten the securing screw an...

Страница 137: ...from the fan casing 4 Check the pulleys for dirt and wear Dirty pulley Clean pulley Worn pulley Have the pulley changed Installing a drive belt 1 Push the new drive belt through the service opening of...

Страница 138: ...working on batteries comply with the following safety signs A warning label with safety signs is attached to the battery Fig 56 Safety signs warning stickers on the battery Take heed of any safety si...

Страница 139: ...ad from the operating mode Battery voltage at the SIGMA CONTROL SMART display Starter battery charge level Charge level Voltage display V Electrolyte density pounds gal Notes 100 12 7 12 85 10 6 Batte...

Страница 140: ...lectrolyte concentration and can destroy the bat tery Top off only with distilled water 2 Check the electrolyte level If the electrolyte level does not reach the mark Top off with distilled water Atta...

Страница 141: ...e 5 Unscrew the battery fixing clamp 6 Replace in the reverse order 7 Make sure the battery is properly secured 8 Turn on the battery isolating switch 9 Replace the panels Battery replacement If the b...

Страница 142: ...ent protection regulations 10 4 11 Checking the fastening of the fuel tank The machine is equipped with a fuel tank or tanks These are fastened with lashing strips and ratchets Precondition The machin...

Страница 143: ...k the insulation of the diesel particulate filter Check the insulation of the diesel particulate filter for proper seating and damage The insulation is damaged Please contact KAESER SERVICE Check the...

Страница 144: ...Check the cooling oil level If oil is not visible Top up the cooling oil 4 Replace the plug in the filler port 5 Attach the panel 10 6 2 Cooling oil filling and topping up Material Cooling oil Funnel...

Страница 145: ...9 Attach the panel Starting the machine and performing a test run 1 Start the machine and run in IDLE until the operating temperature is reached 2 Close the outlet valves 3 Shut down the machine 4 Wai...

Страница 146: ...pan the draining points for oil and coolant from the motor and the com pressor have been installed separately to the exterior The oil is drained using internal hose lines screwed into the drain ports...

Страница 147: ...steps 1 Replace the plug in the oil separator tank filling port 2 Close the access door and replace the panel Dispose of used oil and oil contaminated working materials according to environmental pro...

Страница 148: ...itch 9 Attach the panel Dispose of old cooling oil and any materials or parts contaminated with oil according to envi ronment protection regulations Starting the machine and performing a test run 1 St...

Страница 149: ...on nut 4 Oil return line A Detail Dirt trap oil return line 5 Strainer 6 Sealing ring 7 Screw in connector 8 Nozzle B Detail Dirt trap proportional controller 9 Screw plug 10 O ring 11 Strainer Remove...

Страница 150: ...contaminated materials according to environmental regulations Starting the machine and performing a test run 1 Switch the machine on and run it in IDLE mode for approx 5 minutes 2 Shut down the machin...

Страница 151: ...e dirt trap 5 Air pipe 6 Pipe fitting 7 Cover 8 Fastening screw 9 Control valve 10 Solenoid valve plug 11 Gasket 12 Metal clip 13 Oil separator cartridge 1 Unscrew the union nuts 1 and 3 and place the...

Страница 152: ...formation Information on control valve dirt trap maintenance is given in chapter 10 6 5 Putting in operation 1 Turn on the battery isolating switch 2 Replace any removed panels and close the access do...

Страница 153: ...ne has cooled down All compressed air consumers are disconnected and the air outlet valves are open Damaged air filter element Machine damage due to contaminated intake air Do not try to clean the fil...

Страница 154: ...ent from inside to outside until no further dust develops The blast pipe must be long enough to reach the bottom of the element The tip of the blast pipe must not touch the element Clean sealing faces...

Страница 155: ...ged Point shaped small con cavities can be ignored the axial direction must not exhibit any grooves 1 Slide the seal holder 2 and gasket 3 over the pipe 1 2 Slide the pipe end 8 into the bush without...

Страница 156: ...onnected and the air outlet valves are open The battery isolating switch is turned off Damage can be caused to the machine by water or steam jets Direct water or steam jets can damage or destroy elect...

Страница 157: ...louvre 6 Remove the protective coverings from the air filters 7 Screw the sealing plugs into the drainage openings of the floor pan 8 Turn on the battery isolating switch 9 Replace the panels 10 Star...

Страница 158: ...he battery isolating switch 8 Replace any removed panels and close the service door 9 Start the machine and run up to operating temperature so that excess water is evaporated Clean the cooler fins onl...

Страница 159: ...screw connections with the specific tightening torque Sealed screw connections Screw connections which must not be adjusted are sealed with a coloured locking varnish 1 Damage to the machine caused by...

Страница 160: ...lines are checked at reasonable intervals and are re placed if required see maintenance schedule 10 3 4 1 Comply with all instructions 10 10 1 Replace the fuel lines of the drive engine Have an author...

Страница 161: ...intenance openings The liquid will drain 3 Clean the bungs and maintenance openings 4 Close all maintenance openings with bungs The machine body is sealed 5 Using the cleaning cloth remove any dirt wi...

Страница 162: ...ting pressure of the safety relief valve reaches a maxi mum of Pmax Pmax see table 78 Check in accordance with section Check activating pressure of safety relief valve in the separate operating manual...

Страница 163: ...discharge temperature Have shut down at excessive airend discharge temperature checked Result When the maximum airend discharge temperature is exceeded the SIGMA CONTROL MOBIL controller switches the...

Страница 164: ...and screw the plug fully in again 3 Unscrew and withdraw the plug once more and read off the oil level on the dipstick Oil level at the upper third of the dip stick Oil level is correct If oil does n...

Страница 165: ...vented the pressure gauge reads 0psig All compressed air consumers are disconnected and the air outlet valves are open The battery isolating switch is turned off Fig 69 Cleaning the condensate drain 1...

Страница 166: ...e has automatically vented Pressure gauge reads 0 psig 4 Open the outlet valves 5 Remove both front panels 6 Check the cyclone separator housing and hose line for leaks 7 Replace the panels 10 13 3 Op...

Страница 167: ...end of the hose over the drain port and place the other end in the receptacle 3 Start the compressor engine 4 In order to increase the pressure in the exhaust system partially cover the exhaust disch...

Страница 168: ...service work carried out in this list Date Maintenance task carried out Operating hours Signature Tab 80 Maintenance log 10 Maintenance 10 14 Documenting maintenance and service work 156 Operator Man...

Страница 169: ...is risk of personal injury or damage to the machine resulting from the use of unsuita ble spares or operating fluids materials Use only original parts and operating fluids materials Do not use alterna...

Страница 170: ...manual 11 5 Replacement parts for service and repair With the help of the below spare parts list you can plan your material requirement according to op erating conditions and order the spare parts yo...

Страница 171: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 159...

Страница 172: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 160 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 173: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 161...

Страница 174: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 162 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 175: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 163...

Страница 176: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 164 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 177: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 165...

Страница 178: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 166 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 179: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 167...

Страница 180: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 168 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 181: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 169...

Страница 182: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 170 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 183: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 171...

Страница 184: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 172 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 185: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 173...

Страница 186: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 174 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 187: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 175...

Страница 188: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 176 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 189: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 177...

Страница 190: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 178 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 191: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 179...

Страница 192: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 180 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 193: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 181...

Страница 194: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 182 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 195: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 183...

Страница 196: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 184 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 197: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 185...

Страница 198: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 186 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 199: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 187...

Страница 200: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 188 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 201: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 189...

Страница 202: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 190 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 203: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 191...

Страница 204: ...11 Spares Operating Materials Service 11 5 Replacement parts for service and repair 192 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 205: ...gs with plastic foil and moisture resistant adhesive tape Engine air inlet Compressor air inlet Exhaust silencer 3 Attach the following notice on the instrument panel showing the decommissioning measu...

Страница 206: ...to coat all parts with a protec tive oil film Disconnect the battery the minus terminal first and then the plus ter minal and store in a frost free room Check the battery liquid level 10 9 Check the b...

Страница 207: ...ety Allow transport only by personnel trained in safely dealing with motor vehicles and the trans port of goods 1 There is danger of being run over or crushed by an overturning vehicle Death or severe...

Страница 208: ...t carefully Take care when setting down the machine 1 Incorrect setting down can damage the machine Machine components particularly the support frame can be damaged by incorrectly setting down Set the...

Страница 209: ...tional measures must be taken for the transport of machines by sea or air Please contact KAESER SERVICE for more information Material Squared timbers Straps Carry out a freight securing National direc...

Страница 210: ...r freight The machine is designated as dangerous goods for air freight purposes any disregard can result in a heavy fine 1 Danger of fire or explosion from operating fluids materials The machine incor...

Страница 211: ...disposed of in accordance with environ mental regulations Once these conditions have been fulfilled deliver the machine to an authorised dispozal agent Overview Remove all batteries Drain all operati...

Страница 212: ...ollect the following operating fluids from your machine Designation Drive engine Compressor Fluid Fuel Cooling oil Engine oil Transmission oil Coolant Hydraulic oil Tab 86 Machine fluids Dispose of op...

Страница 213: ...n regulations 12 4 5 Disposing of the machine Precondition All batteries have been removed and delivered to the designated disposal system All operating fluids have been drained and disposed of in acc...

Страница 214: ...r 2 Machine nameplate with system serial number 3 Options label 13 1 2 Identification of the drive engine Fig 75 Identification of the drive engine 1 Engine 2 Position of the nameplate 3 Nameplate wit...

Страница 215: ...ystem 1 Serial number for DPF silencer assembly 2 Serial number for DPF silencer large assembly 13 2 Pipeline and instrument flow diagram P I diagram 13 Annex 13 2 Pipeline and instrument flow diagram...

Страница 216: ...13 Annex 13 2 Pipeline and instrument flow diagram P I diagram 204 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 217: ...13 Annex 13 2 Pipeline and instrument flow diagram P I diagram No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 205...

Страница 218: ...13 Annex 13 2 Pipeline and instrument flow diagram P I diagram 206 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 219: ...13 3 Dimensional Drawing 13 Annex 13 3 Dimensional Drawing No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 207...

Страница 220: ...lable to third parties Subject to development related changes Drawing may be altered only via CAD on frame stationary rx Area covered by the vehicle without towbar 18 41 feet Center of gravity Positio...

Страница 221: ...13 4 Electrical Diagram 13 Annex 13 4 Electrical Diagram No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 209...

Страница 222: ...er than the agreed purpose Neither originals nor reproductions must be forwarded or otherwise made accessible to third parties KAESER KOMPRESSOREN SE Manufacturer Postfach 2143 96410 Coburg 1 Sht a b...

Страница 223: ...3013 04 5 SK 14 Circuit diagram Digital output assembly SFA58UT SK 03013 04 6 SK 15 Circuit diagram analogue input building group SFA58UT SK 03013 04 7 SK 16 Circuit diagram SFA58UT SK 03013 04 8 SK 1...

Страница 224: ...plus unit ON Preheat with glowplug terminal Battery terminal Battery earth Starter Control blue brown yellow green green yellow grey OG PK RD BK VT WH orange pink red black violet white 1 2 3 4 5 6 7...

Страница 225: ...EMERGENCY STOP pushbutton Operating unit SCS Pressure transducer Oil separator Pressure transducer Inlet valve Filter maintenance fuel sensor fuel level temperature sensor Airend discharge temperature...

Страница 226: ...K22 K30 X21 1 X24 1 X25 1 X21 2 X24 2 X25 2 X1 FLRY 0 75mm Control cabinet K20 X100 X31 2 X31 1 W100 PUR 5x0 34 mm W101 PUR 5x0 34mm W106 Oelflex 110 4x0 75 mm W39 Oelflex 110 3G0 75 mm W32 Oelflex 11...

Страница 227: ...B Alternator W2 3 2 3 2 SK 2 1 SK 5 1 SK 3 2 SK 1 4 87 30 500W Preheat with glowplug 16mm 16mm 6mm 30 6mm 30 SK 1 1 31 3 1 M 3 Sht a b c Change Date Date Drawn Released Name 1 07 05 2021 IKM Function...

Страница 228: ...X1 56 2 X1 53 8 X1 49 3 X1 52 9 Plug connection 12 pole X1 50 4 X1 51 10 X1 54 11 X1 55 5 1 5mm K22 1 3 1 3 Sht a b c Change Date Date Drawn Released Name 2 07 05 2021 IKM Function Group of functions...

Страница 229: ...23 5 X1 40 15 X1 41 18 Sensor camshaft X1 2 24 X1 11 7 Banked piston pump X1 12 3 X1 37 14 Sensor coolant temperature X1 19 38 X1 29 9 X1 28 33 Sensor rail pressure X1 1 41 X1 44 28 X1 20 34 39 Intake...

Страница 230: ...9 31 1 X2 52 X2 54 X1 35 X2 50 1 1 86 85 IKM 1 7 87 30 2 2 glow relay X1 21 8 8 KUBOTA X1 36 3 3 85 86 87 87a 30 2 1 Relay Starter IKM 3 4 KL 15 X2 26 KL 50 X2 16 CAN L X2 42 CAN H X2 30 120 CAN Bus E...

Страница 231: ...KAESER N2 8 2 6 2 7 4 31 5 Voltage transformer DC DC 31 4 15 1 N1 8 2 Power supply unit PLC CAN interface 17 40 120 42 17 42 40 30 7 F13 15A 31 1 31 3 30 8 F27 2A 15 2 40 41 42 43 31 4 8 9 10 11 W11 8...

Страница 232: ...6 W28 W28 30 4 F20 5A 4 87 87a 30 5 5 5 4 21 22 6 6 86 85 3 87 87a 30 3 31 1 ECU switching on W12 W12 31 5 Control board outputs 86 85 2 87 87a 30 2 31 2 Relay fuel pump E 8 2 31 3 W33 W33 4 4 1 1 2 2...

Страница 233: ...W101 4 1 3 6 6 Control pressure Inlet valve 7 7 Control board inputs 2 2 3 3 W106 2 3 1 S 1 1 Temperature flow compressor 9 Sht a b c Change Date Date Drawn Released Name 4 07 05 2021 SK Function Grou...

Страница 234: ...21 22 3 4 4 4 EMERGENCY STOP W37 8 8 2 sensor fuel level Control board inputs 3 14 68 14 Alternator 3 8 6 6 Filter maintenance fuel 31 5 31 6 1 9 Sht a b c Change Date Date Drawn Released Name 5 07 0...

Страница 235: ...alve Inlet valve 10 10 31 4 W32 W32 11 11 12 12 Venting valve Control board outputs 31 3 F 8 2 9 Sht a b c Change Date Date Drawn Released Name 6 07 05 2021 SK Function Group of functions D Sitter Fis...

Страница 236: ...Remote ON OFF 51 Remote ON OFF 52 Remove jumper when connecting remote on off 9 Sht a b c Change Date Date Drawn Released Name 7 07 05 2021 SK Function Group of functions D Sitter Fischer C VBBS IN8...

Страница 237: ...Released Name 8 07 05 2021 SK Function Group of functions D Sitter Fischer C IN0 VBBS IN1 GND GND IN2 IN3 VBBS IN4 VBBS IN5 GND GND IN6 IN7 VBBS IN8 VBBS IN9 GND GND IN10 IN11 VBBS GND OUT0 OUT1 GND...

Страница 238: ...K27 GPS Modem 2 8 option oc 9 Sht a b c Change Date Date Drawn Released Name 9 07 05 2021 SK Function Group of functions D Sitter Fischer C GPS GSM 1 2 3 4 5 ON Status 6 7 8 9 10 11 12 13 14 13 Annex...

Страница 239: ...ambda Boersig Boersig Boersig Boersig Boersig Boersig K20 K30 K32 K38 K39 K30 K32 K38 K39 K31 X23 X1 X1 X1 F27 F20 F100 F15 F13 F32 F39 F30 R10 R13 R3 R2 T20 X100 K20N2 K20N1 K20A K20B K20C K20E K20F...

Страница 240: ...K21 S10 S10 S1 S1 X25 B10 B11 B40 B37 Q10 F31 E11 K22 M9 B33 K27 T27 2 Sht a b c Change Date Date Drawn Released Name 2 07 05 2021 Typ notwendige techn Daten z B Steuerspannung Frequenz Einstellbereic...

Страница 241: ...KM 3 4 X24 2 31 1 85 10 K32 3 2 X21 2 31 2 85 10 3 2 X21 2 31 2 12 Control cabinet IKM 3 4 X24 2 31 11 X100 3 6 X21 2 31 3 13 5 K20F 2 7 X25 2 31 3 GND 9 YE X13 2 1 X25 2 31 4 3 7 1 T20 6 3 X31 2 31 4...

Страница 242: ...10 2x0 75mm total 12 Terminals 2 1 IKM M2 1 50 IKM 1 5 IKM G2 2 IG 1 IKM 1 5 IKM G2 3 L 2 3 6 XM9 4 1 1 3 6 XM9 5 2 2 5 6 B33 6 1 3 5 3 XB37 7 2 1 5 4 XB37 8 3 2 3 2 X28 1 9 1 1 3 2 X28 1 10 2 2 3 2 X...

Страница 243: ...X2 53 1 3 K22 2 X2 41 1 5 K22 3 X1 36 1 7 K22 4 X2 30 1 7 K22 5 X2 42 1 8 K22 6 X2 16 1 8 K22 7 X2 26 1 5 K22 8 X1 21 1 3 K22 9 X2 51 IKM 3 4 IKM X42 10 2 IKM 3 4 11 12 total 12 Terminals K38 1 2 1 8...

Страница 244: ...al 12 Terminals 2 2 S10 1 13 1 2 2 S10 2 14 2 5 4 S1 3 11 3 5 4 S1 4 12 4 3 4 S1 5 21 5 3 4 S1 6 22 6 2 1 Control panel 7 2 8 K21 X1 8 2 RD 2 8 K21 X1 9 3 BK 2 8 K21 X1 10 4 WH 2 8 K21 X1 11 5 BU 12 t...

Страница 245: ...Oelflex 110 4x0 75mm total 12 Terminals 4 6 B40 1 1 1 4 5 B40 2 2 2 4 5 B40 3 3 3 4 3 B10 4 1 BN B11 1 BN 4 3 B10 5 3 BU 4 4 B11 6 3 BU 4 4 B10 7 4 BK B11 4 BK 6 2 K1 8 1 6 2 K1 9 2 6 3 K1 10 3 6 3 K7...

Страница 246: ...Switchboard F39 20A F30 25A F100 5A F20 5A F32 20A F15 7 5A F13 15A F27 2A 2 Sht a b c Change Date Date Drawn Released Name 1 07 05 2021 I Sitter Fischer C 13 Annex 13 4 Electrical Diagram 234 Operato...

Страница 247: ...trol panel Control cabinet K21 S1 S10 X100 K31 X21 X23 X31 X25 X24 2 Sht a b c Change Date Date Drawn Released Name 2 07 05 2021 I Sitter Fischer C 13 Annex 13 4 Electrical Diagram No 901779 08 USE Op...

Страница 248: ...Option od Battery charger electrical diagram 13 Annex 13 5 Battery charger electrical diagram 236 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08...

Страница 249: ...the agreed purpose Neither originals nor reproductions must be forwarded or otherwise made accessible to third parties KAESER KOMPRESSOREN SE Manufacturer Postfach 2143 96410 Coburg 1 Sht a b c Chang...

Страница 250: ...ction 1 2 3 4 5 6 7 8 page Block diagram general instructions components option Battery charger components option Engine coolant pre heating 1 Sht a b c Change Date Date Drawn Released Name 1 18 03 20...

Страница 251: ...s b c L1 16 A N Power supply PE Engine coolant pre heating 12V DC 5A 230V AC L1 N PE PE N L1 Battery charger 0 75 mm 7 5A 1 Sht a b c Change Date Date Drawn Released Name 1 18 03 2020 Function Group o...

Страница 252: ...13 6 Fuel circulation diagram 13 Annex 13 6 Fuel circulation diagram 240 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Страница 253: ...13 Annex 13 6 Fuel circulation diagram No 901779 08 USE Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART 241...

Страница 254: ...13 Annex 13 6 Fuel circulation diagram 242 Operator Manual Portable Rotary Screw Compressor MOBILAIR M58utility SIGMA CONTROL SMART No 901779 08 USE...

Отзывы: