Description
The AS Series Powerex Simplex Air Compressors have been
designed, broken-in and tested to meet the most demanding
specifi cations in the pneumatic climate control industry for
low oil carryover and long life.
All Powerex air compressors have reliable operation and
feature high quality construction and components. An
unloading feature is included on all compressors to provide
loadless starting. Oil entrainment is minimized by the use of
lap joint piston rings, low compressor speeds and a special
lubricating oil with a high fl ash point and low carbon
content.
Powerex compressor motors are NEMA Class B design. Single-
phase motors have built-in overload protection and a DPST
disconnect switch. Three-phase motors require a manual or
magnetic starter and three overload heater coils which may
be ordered as a factory mounted and wired option.
Safety Guidelines
This manual contains information that is very important
to know and understand. This information is provided for
SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help
recognize this information, observe the following symbols.
Danger indicates an imminently
hazardous situation which, if
not avoided, WILL result in death or serious injury.
Warning indicates a potentially
hazardous situation which, if
not avoided, COULD result in death or serious injury.
Caution indicates a potentially
minor or moderate injury.
Notice indicates important
information, that if not
followed, may cause damage to equipment.
NOTE:
Information that requires special attention.
CALIFORNIA PROPOSITION 65
This product or its power cord
may contain chemicals known
to the State of California to cause cancer and birth defects or
other reproductive harm. Wash hands after handling.
Specifi cations
Product
AS Series Powerex Simplex Air Compressors
Performance
Specifi cations
See Page 2
Lubrication
Splash Lubrication System
Operating
Voltages
1Ø
115 - 280 / 230 Volts, 60 Hz
3Ø
280 - 230 / 460 Volts, 60 Hz
Compression
Cycle
Single-Stage
Motor
Overload
Protection
1Ø
Built-in Thermal Overload (Standard)
3Ø
Magnetic Starter and Three Thermal
Overload Switches (Optional)
Pressure
Settings
Cut-In: Factory Set at Approximately 70 psig (490 kPa)
Cut-Out: Factory Set at Approximately 90 psig (630 kPa)
Overpressure
Protection
ASME Safety Valve Factory Set and Sealed at
Approximately 115 psig (805 kPa)
Outlet Air
Connections
3/4 inch NPT (30, 60, and 80 Gallon Tanks)
Tank Sizes
30 Gallon to 80 Gallon
California
Ordinance
462 (L) (2)
Meets Requirements of this Ordinance
Tank Isolation
Standard All Units
The performance specifi cations are nominal and conform to acceptable industry standards. For application at conditions beyond these
specifi cations, consult the local Powerex offi ce. Powerex shall not be liable for damages resulting from misapplication or misuse of its products.