Branch 28 Smart Start Crank Time
Selecting engine crank time automatically selects the tachless mode and one of three crank
times. If the normal engine crank time is too short increase the time by selecting one of the
two additional extended crank time options. Normal - 0.8Sec., Extended - 1.0Sec., Super Ex-
tended - 1.4Sec. Tachless Mode. Determines the engine status using an advanced software
routine, without requiring connection to the vehicle
’
s tachometer. Tachless operation may not
be compatible with some vehicles or in severe temperatures, in which case the tach wire must
be connected.
Branch 29 Smart Start Temp. Comp.
Adjusts crank time to compensate for temperature variations.
Branch 30 Engine Sense Mode Smart Sense/Tach Mode
Selects between Smart Sense or Tach mode. Note Tach mode is the preferred method of sens-
ing engine run
Branch 31 Remote Start Program
This dual program branch sets the engine mode for Gas or Diesel, and learns the vehicle
’
s
RPM threshold. For installation into a diesel equipped vehicle, first set the engine type to
diesel before learning RPM. RPM Learn/Tach Monitor. start the engine, enter Branch 21, the
LED light will flash continuously to indicate it is reading the tach signal. Press Button 1 to
learn the vehicle
’
s tach signal. The siren will chirp and the LED will flash once to confirm
learning of the tach signal. The siren will chirp four times and the LED will flash four times if
the tach signal was not learned. Tach Monitor mode: monitors the vehicle
’
s tach wire (or a
fuel injection wire) in real-time to determine engine status and adjust starter crank time auto-
matically. Gas Engine. Sets the engine type for Gasoline. Diesel Engine. Sets the engine type
for Diesel and monitors the glow plug input to make sure the glow plugs are warm before
cranking the starter. If the glow plug wire is not connected, the built-in timer waits 15 seconds
before automatically cranking the starter.
Branch 32 Acc/Ignition Output (Pin i3)
This setting selects whether the system will output an accessory signal or ignition signal to Pin
i3 brown wire.
Branch 33 Wait to Start Input
Selects between negative and positive input polarity on Pin A4
Branch 34 Turbo Timer
When enabled, if the emergency brake has been applied Ignition power will be kept On for a
predetermined time (2 minutes Factory Default) upon arrival.
Branch 35 Ignore Open Door Report
Bypasses the open zone warning chirps for vehicles equipped with a residual dome light cir-
cuit that remains on for a period of time after closing the door.
Page 25
Содержание K9Caller
Страница 14: ...Page 14 ...